Evaluation of Ves-Matic Cube 200--an automated system for the measurement of the erythrocyte sedimentation rate.

نویسندگان

  • E Perovic
  • L Bakovic
  • A Valcic
چکیده

Ves-Matic Cube 200 is fully automated analyzer that performs erythrocyte sedimentation rate (ESR) measurement using the standard ethylenediaminetetraacetic acid blood sample tube, thus markedly reducing the analytical time and avoiding the need for an extra blood sample. The aim of this study was to assess the automatic Ves-Matic Cube 200 system for the measurement of ESR in comparison with the original International Council for Standardization in Hematology reference method (Westergren). The evaluation comprised accuracy which was established using a 95% confidence interval (CI) for the mean difference between Ves-Matic Cube 200 and Westergren method (mean of difference: 0.47+/-6.84 mm/h; 95% CI: -0.376 to 1.325 mm/h), within-run imprecision for samples with ESR values of 9, 42 and 95 mm/h (coefficients of variation: 9.19%, 13.88% and 5.66%, respectively) and method comparison (rho=0.95; Passing-Bablok regression equation: Y=-0.0435+1.0435 X; bias: -0.5; limits of agreement: -13.9 to 12.9). Stability was estimated after 24 h storage either at 4 degrees C and room temperature (mean of differences: -1.91 mm/h; 95% CI: -4.852 to 1.037 mm/h and mean of differences: -12.48 mm/h; 95% CI: -16.580 to -8.390 mm/h, respectively). The obtained results suggest that the Ves-Matic Cube 200 automated analyzer is reliable system for the measurement of ESR in clinical laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Ves-Matic Cube 200 erythrocyte sedimentation method: comparison with Westergren-based methods.

The erythrocyte sedimentation rate (ESR) is still a widely used parameter for acute phase inflammation. Recently, new methods based on direct undiluted measurement of ESR in a standard EDTA tube have been developed. We evaluated the analytic performance of one of these new methods, the Ves-Matic Cube 200 (Diesse Diagnostica Senese, Siena, Italy), and compared it with several established Westerg...

متن کامل

Assessment of Diesse Ves-matic automated system for measuring erythrocyte sedimentation rate.

Measurement of the erythrocyte sedimentation rate (ESR) using a closed tube system reduces the biohazard risk to laboratory staff. The Diesse Ves-matic system offers manual or vacuum collection of blood into plastic tubes, automated mixing of the sample, and automated reading of the end point after 20 minutes of sedimentation. This system was compared with the 1977 Westergren ESR method of the ...

متن کامل

Aberration of Erythrocyte Sedimentation Rate by Zinc Nanoparticles

Dear Editor, erythrocyte sedimentation rate (ESR) is a useful basic clinical pathology laboratory investigation. It can be helpful in diagnosis and follow-up of several diseases. At present, a new automated method with proven reliability is available for ESR test  (1). Here, the authors report on observation on a laboratory experiment to test the effect of zinc nanoparticles on ESR results. The...

متن کامل

Internal Quality Control for Erythrocyte Sedimentation Rate Using Patient Blood Sample

The erythrocyte sedimentation rate (ESR) test continues to be used as an important tool in many laboratories; either manually or as automated method. When automation is applied in clinical laboratories, it is imperative that reliable methods for calibration and appropriate control materials are available for monitoring the accuracy and precision of the results generated. But when the commercial...

متن کامل

Can we consider erythrocyte sedimentation rate and C-reactive protein as a severity index in pemphigus vulgaris?

Background: Erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) are 2 inflammatory indicators that increase in many pathologic and physiologic conditions. Pemphigus vulgaris (PV) is an autoimmune skin disease in which autoantibodies against desmogleins cause acantholysis. In this study we have measured ESR and CRP levels in patients with PV to evaluate the relationship between an ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of laboratory hematology

دوره 32 1 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2010