Practical considerations for prostate HDR brachytherapy.

نویسنده

  • Eric D Slessinger
چکیده

PURPOSE A process for prostate high-dose-rate (HDR) brachytherapy was developed and implemented successfully in the community hospital setting. The practical aspects of the program are reviewed and may serve as a foundation for clinics interested in offering this clinical service. METHODS AND MATERIALS A generic needle distribution geometry was established to accommodate target volumes of variable size. A system to identify and assign treatment channels to each implant needle was devised. The computerized tomography (CT)-based treatment planning was used with dose constraints defined for sensitive structures and target uniformity. Implant needle stability was promoted by supporting the patient on a CT compatible padded sliding board. A process that aligns dwell position to CT imaging without the use of radiographic markers was followed. Graphical optimization of dwell times was used to generate the treatment dose distributions. RESULTS Prostate HDR brachytherapy as a boost or as monotherapy has been offered in a program that has evolved over the past 8 years. Practical aspects of the program promote its feasibility and precision. Collaboration with commercial entities has also led to the development of products that support the technique. CONCLUSIONS Prostate HDR brachytherapy offers a relatively high degree of dose distribution control in comparison with other prostate radiotherapy modalities. The practical aspects described offer assurance to achieve that goal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High dose rate brachytherapy for prostate cancer.

High dose rate (HDR) afterloading brachytherapy in the management of localised prostate cancer has practical, physical and biological advantages over low dose rate seed brachytherapy. There are no free live sources used, no risk of source loss and since the implant is a temporary procedure following discharge no issues with regard to radioprotection use of existing facilities. Adequate coverage...

متن کامل

High-dose-rate Brachytherapy for Prostate Cancer

Introduction/Background Over the last 2 decades, significant technical advancements have improved the delivery of prostate brachytherapy. The transrectal ultrasound-guided implant technique is the backbone of modern prostate brachytherapy. Whether it is permanent or temporary, ie, low-dose-rate (LDR) or high-dose-rate (HDR), respectively, both use similar image-guided techniques for inserting s...

متن کامل

Efficacy and Safety of High-Dose-Rate Brachytherapy of Single Implant with Two Fractions Combined with External Beam Radiotherapy for Hormone-Naïve Localized Prostate Cancer

The purpose of this study was to evaluate the efficacy and safety of high-dose-rate (HDR) brachytherapy of a single implant with two fractions plus external beam radiotherapy (EBRT) for hormone-naïve prostate cancer in comparison with radical prostatectomy. Of 150 patients with localized prostate cancer (T1c-T2c), 59 underwent HDR brachytherapy plus EBRT, and 91 received radical prostatectomy. ...

متن کامل

The emerging role of high-dose-rate (HDR) brachytherapy as monotherapy for prostate cancer

High-dose-rate (HDR) brachytherapy as monotherapy is a comparatively new brachytherapy procedure for prostate cancer. In addition to the intrinsic advantages of brachytherapy, including radiation dose concentration to the tumor and rapid dose fall-off at the surrounding normal tissue, HDR brachytherapy can yield a more homogeneous and conformal dose distribution through image-based decisions fo...

متن کامل

Gold marker displacement due to needle insertion during HDR-brachytherapy for treatment of prostate cancer: A prospective cone beam computed tomography and kilovoltage on-board imaging (kV-OBI) study

PURPOSE To evaluate gold marker displacement due to needle insertion during HDR-brachytherapy for therapy of prostate cancer. PATIENTS AND METHODS 18 patients entered into this prospective evaluation. Three gold markers were implanted into the prostate during the first HDR-brachytherapy procedure after the irradiation was administered. Three days after marker implantation all patients had a C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brachytherapy

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 2010