A Photometric System for Automatically Reading Concentration.
نویسندگان
چکیده
Spectrophotometric or colorimetric data are normally obtained in some type of photometric unit and must be dealt with mathematically to provide a final result expressedin concentration. Such mathematical operationsare time-consuming, require data transfer, and are subject to human error. A photometric systemhas been devised which can be adjusted to perform calculations automatically and provide direct readout of concentration. This system combines logarithmic conversionof %T with control of both m and b constantsin the straight-line equation, y = mx + b, in which y is absorbance,m is slope, x isconcentration, andb is the blank correction. The systemalso provideslinearizing compensationfor those reactions which do not follow the Beer-Lambert law. The calibration procedurefor the systemis described,as is the linearization of nonlinearstandard curves.
منابع مشابه
Heated Inlet Sample Conditioning Effects on Remote Dust Monitoring
Under high ambient humidity conditions, photometric mass measurements have been reported to over-estimate mass concentration readings when compared to a reference method. This is largely attributed to water-uptake, resulting in hygroscopic growth of the aerosol particles. When the aerosol particles increase in size, they scatter more light, resulting in higher mass concentration readings by the...
متن کاملComparison of Respirable Particulate (PM4) Measturements from Direct- Reading Photometric Instruments and a Gravimentric Sampling Method
The National Environmental Management: Air Quality Act of 2004 states that people have the right to clean air and a healthy environment. Residents of low-income settlements are exposed to high concentrations of indoor air pollution due to the burning of solid fuels such as low-grade coal and wood for space heating and cooking. Long term exposure leads to degradation in the quality of life exper...
متن کاملDiscrete automated chemistry system with tableted reagents.
An instrument/reagent system with tableted reagents has been developed for performing ultraviolet/visible photometric assays. Preformed disposable plastic cuvettes pass through a stationary track every 5 s, providing a maximum throughput of 698 tests/h. The photometric system consists of a single light source with a separate set of light guides for each of eight photometer stations; bichromatic...
متن کاملDesign and construction of a portable unite for measuring body-fluid components
Introduction: In the laboratory, the time required to measure body-fluids components is usually one to two working days. The laboratory methods require sample preparation and instrument cleaning after the sample reading. In emergency scenarios, the physician does not have much time to make a clinical decision. To solve these challenges, a portable system for measuring the body fluids components...
متن کاملDetection of false positives by incorporation of a confirmatory blocking test into a commercial enzyme-linked immunosorbent assay specific for adenovirus antigen.
A blocking test was incorporated into the commercial IDEIA Adenovirus test (DAKO Diagnostics Ltd., Cambridgeshire, UK) to detect false positive results when faecal specimens were tested for adenovirus antigen. Immune rabbit serum raised against pooled adenovirus particles from human faecal specimens, together with the pre-immune serum, was used. Assessment of positive showed that false positive...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 10 شماره
صفحات -
تاریخ انتشار 1964