Diagnostics for a 1.2 kA, 1 MeV, Electron Induction Injector
نویسندگان
چکیده
We are constructing a 1.2 kA, 1 MeV, electron induction injector as part of the RTA program, a collaborative effort between LLNL and LBNL to develop relativistic klystrons for Two-Beam Accelerator applications. The RTA injector will also be used in the development of a high-gradient, low-emittance, electron source and beam diagnostics for the second axis of the Dual Axis Radiographic Hydrodynamic Test (DARHT) Facility. The electron source will be a 3.5"-diameter, thermionic, flat-surface, m-type cathode with a maximum shroud field stress of approximately 165 kV/cm. Additional design parameters for the injector include a pulse length of over 150 ns flat top (1% energy variation), and a normalized edge emittance of less than 200 π-mm-mr. Precise measurement of the beam parameters is required so that performance of the RTA injector can be confidently scaled to the 4 kA, 3 MeV, and 2-microsecond pulse parameters of the DARHT injector. Planned diagnostics include an isolated cathode with resistive divider for direct measurement of current emission, resistive wall and magnetic probe current monitors for measuring beam current and centroid position, capacitive probes for measuring A-K gap voltage, an energy spectrometer, and a pepperpot emittance diagnostic. Details of the injector, beam line, and diagnostics are presented.
منابع مشابه
Progress on the Relativistic Klystron Two-Beam Accelerator Prototype
The technical challenge for making two-beam accelerators into realizable power sources lies in the creation of the drive beam and in its propagation over long distances through multiple extraction sections. This year we have been constructing a 1.2-kA, 1-MeV, electron induction prototype injector as a collaborative effort between LBL and LLNL. The electron source will be a 3.5” -diameter, therm...
متن کاملThe Darht-ii Electron Injector
The injector for the second axis of the Dual-Axis Radiographic Hydrotest Facility (DARHT) is being designed and constructed at LBNL. The injector consists of a single gap diode extracting 2 μs, 2 kA, 3.2 MeV electron beam from a 6.5 inches diameter thermionic dispenser cathode. The injector is powered through a ceramic column by a Marx generator. We also investigated the possibility of extracti...
متن کاملDesign of the ETA - II / Snowtron Double Pulse Target Experiment *
We have modified the single pulse target experimental facility[1] on the Experimental Test Accelerator II (ETAII) to perform the double pulse target experiments to validate the DARHT-II[2, 3] multi-pulse target concept. The 1.15 MeV, 2 kA Snowtron injector will provide the first electron pulse. The 6 MeV, 2 kA ETA-II beam will be used as the probe beam. Our modeling indicates that the ETA-II/Sn...
متن کاملThe Linac Coherent Light Source Photo-Injector Overview and Some Design Details
The Linac Coherent Light Source (LCLS) is a SASE free electron laser using the last 1/3 of the SLAC two mile linac to produce 1.5 to 15 angstrom x-rays in a 100 meter long undulator for use in a variety of x-ray science experiments. In order to satisfy the demanding electron beam requirements, a new 135 MeV photo-injector will be built in an existing, off-axis vault at the 2/3 point of the main...
متن کاملSeptum and Kicker Pulsers for the LNLS 500-MeV Booster Synchrotron
Brazilian National Synchrotron Light Laboratory (LNLS) has commissioned its new 500-MeV booster synchrotron injector. In this paper we present an overview of the septum and kicker pulse circuits now in operation. Half-sine wave septum current pulses range from 6.1 kA to 7.3 kA with widths around 80 μs. Injection and extraction kicker circuits are capable of delivering currents up to 650 A and 1...
متن کامل