Microdroplet fluorochromatic assay for the enumeration of white cells (WBCs) in WBC-reduced blood components: validation and application for evaluating newly developed WBC-reduction filters.
نویسندگان
چکیده
BACKGROUND Sensitive and accurate counting methods are required to assess the residual white cells (WBCs) in WBC-reduced blood components. The Nageotte hemocytometer, widely used for this purpose, is cumbersome, and its efficacy is dependent upon the skill of the operator. The performance of a simple fluorochromatic assay using tissue-typing microdroplet trays is presented here. STUDY DESIGN AND METHODS Undiluted samples of blood components were mixed with a fluorochromatic dye in trays. WBCs were counted under an epifluorescence microscope. The accuracy and sensitivity of this method were compared with those of the reference Nageotte hemocytometer method by using serial dilution of samples of platelets and red cells containing known concentrations of WBCs and by calculating the standard curves. The Nageotte hemocytometer and the microdroplet fluorochromatic assay (MFA) were also compared in terms of count correlation and reproducibility in 320 paired counts of plateletpheresis samples. MFA was used to evaluate a newly developed WBC-reduction red cell filter. RESULTS The MFA for platelets and red cells was linear to 0.1 and 0.03 WBCs per microL, respectively. The linear regression line of log10 MFA versus log10 Nageotte method had a slope of 0.963, intercept of -0.04, and r2 of 0.968. The Nageotte method gave an estimation of WBC content 12 to 20 percent greater than that of the MFA. The MFA, with a larger neat sample volume, showed precision comparable to that of the Nageotte method. The filters demonstrated a median WBC reduction of 4.8 log10. CONCLUSION The MFA is a sensitive and accurate method for quality control processes to assess the residual WBCs in WBC-reduced blood components.
منابع مشابه
A prospective, randomized clinical trial of universal WBC reduction.
BACKGROUND Recipient exposure to allogeneic donor WBCs results in transfusion complications for selected populations of recipients. Whether or not WBC reduction should be universally applied is highly controversial. STUDY DESIGN AND METHODS In a general hospital, a randomized, controlled clinical trial of conversion to universal WBC reduction was conducted. Patients (11%) with established med...
متن کاملWBC filtration of whole blood after prolonged storage at ambient temperature by use of an in-line filter collection system.
BACKGROUND Before-storage WBC reduction by filtration appears to be an effective way to prevent transfusion-associated complications. It also has superiority over WBC reduction at the time of transfusion (bedside), due to the many variables associated with such practice and the difficulty in performing adequate quality control. To determine the adaptability of collection systems containing in-l...
متن کاملTc-99m Labeled HMPAO white Blood Cell Scintigraphy in a patient with Hip Prosthesis
Background The ability to follow the distribution and migration of biologically active cells in human is essential for the development of cell-based therapies and diagnostics. Nuclear medicine imaging is widely applied in clinic as an attractive technique for in vivo WBC and stem cell tracking. The aim of this study was to evaluate prosthesis infection of a 51 years old man with previous histo...
متن کاملIsolation and two-step classification of normal white blood cells in peripheral blood smears
INTRODUCTION An automated system for differential white blood cell (WBC) counting based on morphology can make manual differential leukocyte counts faster and less tedious for pathologists and laboratory professionals. We present an automated system for isolation and classification of WBCs in manually prepared, Wright stained, peripheral blood smears from whole slide images (WSI). METHODS A s...
متن کاملProcess control of filtered red blood cells: which counting method?
Various counting methods have been described and reported for process control of leuco-epleted blood components. The recent production of high-efficiency leucocyte removal filters intensifies the need for sensitivity in determining the ever lower residual concentration of white cells (WBCs) in filtered units. In order to assess which method was the most efficient and feasible in the laboratory ...