OBJECTIVES This study was designed to study the behavior of a stent deployed inside human stenotic aortic valves. BACKGROUND Endovascular valved stent (VS) implantation is a promising new therapy for patients with severe calcific aortic stenosis (AS). The precise characteristics of stent deployment in humans have been poorly studied so far. METHODS Thirty-five patients with severe AS were included in the study. Sixteen patients (46%) had bicuspid aortic valves. A self-expandable stent specifically designed for VS implantation was deployed intraoperatively inside the aortic valve before surgical aortic valve replacement. RESULTS In tricuspid aortic valves, the shape of stent deployment was circular, triangular, or elliptic in 68%, 21%, or 11%, respectively. Noncircular stent deployment was frequent in bicuspid aortic valves (the elliptic deployment being the rule [79%]), and stent underdeployment was constant. The incidence of gaps between the stent external surface and the aortic valve did not differ between tricuspid and bicuspid valves (58% vs. 43%; p = 0.49). Sharp calcific excrescences protruding inside the stent lumen were present in 3 cases (9%). Ex vivo study of a homemade VS confirmed that the regularity of the coaptation line of the leaflets was critically dependent on the presence or the absence of stent misdeployment. CONCLUSIONS Stent misdeployment was constant in bicuspid valves and occurred in one-third of cases of tricuspid valves. Premature failure of implanted VS (secondary to valve distortion or traumatic injury to the leaflets by calcific excrescences) might be an important concern in the future.
منابع مشابه
Percutaneous aortic valve replacement: computed tomography scan after valved stent implantation in human cadaver hearts.
Computed tomography scans were performed before and after aortic valve resection with consecutive implantation of a valved stent in human hearts with highly calcified aortic valves in situ (n=2). This demonstrates that the valved stent shows better fitting in the annulus after removal of the native valve.
متن کاملPercutaneous valved stent implantation above the coronary ostia.
BACKGROUND In recent years, some experimental and clinical studies on transcatheter aortic valve implantation (TAVI) have been conducted. TAVI is indicated in patients with calcified pure or predominant aortic stenosis. The risk of this technique is still high. Aortic valved stent implantation above the coronary ostia might avoid blocking the coronary ostia. METHODS AND RESULTS Twenty healthy...
متن کاملSteps toward percutaneous aortic valve replacement.
BACKGROUND To date, the surgical approach is the only option to replace the aortic valve. Percutaneous pulmonary valve replacement has recently opened new perspectives on transcatheter replacement of cardiac valves. We report our experience of aortic valve replacement through a percutaneous technique in lambs. METHODS AND RESULTS A bovine jugular vein containing a valve was dissected and sutu...
متن کاملCarotenoids Co-Localize with Hydroxyapatite, Cholesterol, and Other Lipids in Calcified Stenotic Aortic Valves. Ex Vivo Raman Maps Compared to Histological Patterns
Unlike its application for atherosclerotic plaque analysis, Raman microspectroscopy was sporadically used to check the sole nature of bioapatite deposits in stenotic aortic valves, neglecting the involvement of accumulated lipids/lipoproteins in the calcific process. Here, Raman microspectroscopy was employed for examination of stenotic aortic valve leaflets to add information on nature and dis...
متن کاملRelation of weights of operatively excised stenotic aortic valves to preoperative transvalvular peak systolic pressure gradients and to calculated aortic valve areas.
OBJECTIVES The purpose of this study was to correlate the weights of operatively excised stenotic aortic valves to preoperative transvalvular peak systolic gradients and to calculated aortic valve areas. BACKGROUND No previous publication has correlated the weights of stenotic aortic valves to the transvalvular gradients or to the calculated aortic valve areas. METHODS We weighed operativel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 51 5 شماره
صفحات -
تاریخ انتشار 2008