Multiplanar and 3D imaging of the central airways: comparison of image quality and radiation dose of single-detector row CT and multi-detector row CT at differing tube currents in dogs.

نویسندگان

  • Phillip M Boiselle
  • Giuseppe Dippolito
  • John Copeland
  • Haejin Kang
  • Muneeb Ahmed
  • Dawn Weeks
  • Elkan Halpern
  • S Nahum Goldberg
چکیده

PURPOSE To compare in an animal model the image quality of multiplanar reformation and three-dimensional (3D) reconstruction images of the central airways by using single-detector row computed tomography (CT) and multi-detector row CT at varied tube currents and to compare radiation dose. MATERIALS AND METHODS Five dogs each underwent five consecutive helical CT examinations (one single-detector row CT examination at 240 mA and four multi-detector row CT examinations at 240, 120, 40, and 20 mA), with 0.8-second gantry rotation time. Multiplanar reformation and 3D reconstruction images were created from each of the 25 CT acquisitions. The images were randomized and blindly reviewed with consensus agreement by three radiologists who graded image quality by using a five-point scale. In a separate review, the three radiologists independently used a four-point scale to rank the comparative image quality of the multi-detector row CT 3D images, while blinded to specific tube currents. The radiation doses were measured for each type of scan, and the relative radiation dose length products that were normalized to single-detector row CT values were used to compare radiation doses of the various CT techniques. Statistical analysis was performed with the Wilcoxon signed-rank test and the Friedman analysis of variance test. RESULTS Image quality was consistently ranked higher for multi-detector row CT images than for single-detector row CT images (P =.03). Although there were no distinguishable differences between images obtained with multi-detector row CT at 240, 120, or 40 mA, images obtained with 20 mA were given a significantly (P =.04) lower relative rank (mean, 2.4) than those obtained with higher tube currents (mean, 1.4-1.7). Multi-detector row CT radiation doses were 1.64, 0.82, 0.27, and 0.14 (for 240-, 120-, 40-, and 20-mA multi-detector row CT, respectively) relative to the dose for 240-mA single-detector row CT. CONCLUSION Multi-detector row CT is superior to single-detector row CT for multiplanar and 3D imaging of the central airways. Substantial dose reductions can be made, while maintaining high image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Introduction to the Language of Three - dimensional Imaging with Multidetector CT 1 Neal

The recent proliferation of multi–detector row computed tomography (CT) has led to an increase in the creation and interpretation of images in planes other than the traditional axial plane. Powerful three-dimensional (3D) applications improve the utility of detailed CT data but also create confusion among radiologists, technologists, and referring clinicians when trying to describe a particular...

متن کامل

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...

متن کامل

AAPM / RSNA PHYSICS TUTORIAL 1495 AAPM / RSNA Physics Tuto - rial for Residents Physics of Cardiac Imaging with Multiple - Row Detector CT 1

Cardiac imaging with multiple-row detector computed tomography (CT) has become possible due to rapid advances in CT technologies. Images with high temporal and spatial resolution can be obtained with multiple-row detector CT scanners; however, the radiation dose associated with cardiac imaging is high. Understanding the physics of cardiac imaging with multiple-row detector CT scanners allows op...

متن کامل

Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose

Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 228 1  شماره 

صفحات  -

تاریخ انتشار 2003