Loss of radiobiological effect of imaging dose in image guided radiotherapy due to prolonged imaging-to-treatment times.
نویسنده
چکیده
PURPOSE Increased use of cone beam CT guidance in image guided radiotherapy has prompted the inclusion of the imaging dose in treatment plans, thus using imaging beams to treat tumors. Sublethal radiation damage repair during tau(d), the time between imaging and treatment, could reduce the effectiveness of the imaging dose, resulting in tumor underdosage. The theoretical magnitude of this effect was quantified using radiobiological modeling. METHODS The therapeutic effective dose (TED), which, if delivered using only therapeutic beams, would result in the same tumor cell survival as for both the imaging and therapeutic beams, was derived using the generalized linear-quadratic model. The correction factor P(d) by which therapeutic dose can be scaled to compensate for sublethal damage repair was also derived. TED and P(d) are dependent on alpha/beta, sublethal damage repair half-time (T(r)), imaging dose (D(I)) and dose rate (D(I)), therapeutic dose (D(T)) and dose rate (D(T)), and tau(d). TED and P(d) were calculated as a function of tau(d), and each parameter was varied independently while holding the remaining parameters at their reference values. The reference values were based on prostate cancer cells and were D(p) = D(I)+D(T) = 1.8 Gy, D(I)/D(p) = 5%, D(I) = 0.33 Gy/min, D(T) = 1.0 Gy/min, alpha/beta = 3.1 Gy, T(r) = 16 min, and tau(d) = 0 min. Estimates of the expected values of TED and P(d), (TED) and (P(d)), were calculated using tau(d) and D(T) distributions from a few thousand prostate treatment fractions. RESULTS For a typical tau(d) value of 5.0 min and all other parameters set to their reference values, TED was 0.5% lower than the prescription dose D(p). For tau(d) = 20 min and all other parameters at reference conditions, TED dropped by 5% relative to D(p) when D(I)/D(p) was 20% and by 2% relative to D(p) when alpha/beta = 1 Gy or T(r) = 5 min. TED/D(p) varied more with D(T) than D(I) when tau(d) < or = 20 min, varying by up to 1% over 0.05 < or = D(T) < or = 10 Gy/min and by less than 0.1% over 0.05 < or = D(I) < or = 2.0 Gy/min. Under the reference conditions, (TED) was lower than D(p) by 0.5%. For the extreme D(I)/D(p) = 20% and all other parameters at their reference values, setting alpha/beta = 1 Gy resulted in (TED) dropping below D(p) by 2.5% and setting T(r) = 5 min resulted in (TED) dropping below D(p) by 4%. For tumors with a T(r) of 16 min or greater and alpha/beta of 11 Gy, (TED) dropped below D(p) by 0.2% or less. CONCLUSIONS For prostate tumors receiving a reasonable percentage of 5% of their total dose from imaging beams, the theoretical drop in (TED) relative to D(p) was 0.5%. This loss could be accounted for during treatment planning by scaling the therapeutic dose by the expected sublethal damage repair factor (P(d)). For nonprostate tumors with alpha/beta values of 11 Gy, the theoretical drop in (TED) relative to the reference TED was low at 0.2%.
منابع مشابه
Health technology assessment of image-guided radiotherapy (IGRT): A systematic review of current evidence
Background: Image-guided radiotherapy used multiple imaging during the radiation therapy course to improve the precision and accuracy of health care provider's treatment. Objectives: This study aims to assess the safety, effectiveness and economic aspects of image-guided radiation therapy for decision-making about this technology in Iran. Methods: In this study, the most important med...
متن کاملComparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications
Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...
متن کاملEvaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter
Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was use...
متن کاملDosimetric and Radiobiological Evaluation of Multiparametric MRI-guided Dose Painting in radiotherapy of Prostate Cancer
Introduction: Radiotherapy is one of the treatment options for locally advanced prostate cancer, however with standard radiation doses it is not always very effective. One of the strategies to improve the efficiency of radiotherapy is increasing the dose. In this study to increase tumor local control rates a new radiotherapy method, known as dose painting (DP) was investigated....
متن کاملA prospective radiobiological study of acute esophagitis and swallowing dysfunction in head-and-neck radiotherapy
Introduction: Esophagitis is one of the main causes of swallowing dysfunction after radiation therapy (RT) for head and neck cancer (HNC).It significantly affects patients’ quality of life as well as having a potentially negative impact on their long term survival. However, little has been investigated on the dose-response and normal tissue complication probability (NTCP) of es...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 37 6Part1 شماره
صفحات -
تاریخ انتشار 2010