A new photon branch in the standard Panasonic UD-802 Dose Algorithm at the CIEMAT External Dosimetry Service
نویسندگان
چکیده
The standard dose algorithm provided by Panasonic to be used with the four element UD-802 TLD badge is widely employed in Personnel Dosimetry Services all around the world. The algorithm was developed to satisfy the obsolete standard ANSI 13.11-1983 that was reviewed in 1993 (HPS N13.11-1993) and revised again in 2001 (HPS N13.11-2001) including differences in the NIST x-ray techniques used as test spectra and updated values of the air kerma to dose equivalent conversion factors. In addition, the x-ray reference radiations employed in Spain and in most of the european countries for calibrating dosemeters are the specified in the ISO 4037-1 (1996) and the conversion coefficients from air kerma to dose equivalent are those given in the ISO 4037-3 (1999). All these conditions made necessary a deep revision of the photon correction factors and categories included in the photon branch of the standard UD-802 dose algorithm. With this aim, dosemeters from the CIEMAT External Dosimetry Service (EDS) were irradiated at the CIEMAT Reference Laboratory for X-ray at Protection Level employing the X-ray from the narrow-spectrum series given by the ISO 4037-1 (1996) and the ISO water slab phantom. The results allowed testing the energy response of the four element of the dosemeter, to define its real discrimination capability and to determine the correction factors that best accommodate the results to the reference doses. This process concluded with the proposal of a completely new photon branch in the standard UD-802 dose algorithm that has recently undergone a blind test to guarantee its performance. This work presents the proposal of the new photon branch and the comparison between the results of the blind test from both the modified and the standard UD-802 dose algorithm.
منابع مشابه
In vivo dosimetry of intraoral stent using TLD during external photon beam radiotherapy of oral cavity
Introduction: Individual oral stent is a mouth-opening device that used in head and neck cancer radiotherapy with the intention of decreasing radiation dose to health tissues. The aim of this study was to check the dose delivered to both the hard palate and tongue when patient uses the stent during radiotherapy of tongue carcinoma. Methods and materials<stron...
متن کاملPhoton Dosimetry Quality Audit of Radiotherapy Centers in Iran: SSDL's On-Site Visit Program During 2007-2017
Introduction: A dosimetric audit is a quality assurance process (QA) that allows the accuracy of dosimetric and geometric precision to accurately control the delivery of doses. They can be used to evaluate the accuracy of radiation delivery at different radiotherapy centers. Differences in prescriptive doses, depending on the severity of the differences, have potential conseque...
متن کاملStandard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کاملMeasuring midline dose without build-up cap for patients with brain tumor undergoing 15MV external radiotherapy by using EBT3 Gafchromic film
Introduction: The Purpose of this study has been measuring midline dose for the patients undergoing brain radiotherapy without any need to build-up cap. Materials and Methods: The study was performed on 28 patients with brain tumor undergoing 15 MV radiotherapy by a Siemens LINAC. To estimate the midline dose, the entrance and exit doses were calculated b...
متن کاملThe Impact of Nano-Sized Gold Particles on the Target Dose Enhancement Based on Photon Beams Using by Monte Carlo Method
Objective(s): In this study we evaluate the impact of the different aspects of Gold Nano-Particles (GNPs) on the target absorptive Dose Enhancement Factor (DEF) during external targeted radiotherapy with photon beams ranging from kilovolt to megavolt energies using Monte Carlo simulation. Methods: We have simulated the interaction of photon beams wi...
متن کامل