A new technique for precisely and accurately measuring lumbar spine bone mineral density in mice using clinical dual energy X-ray absorptiometry (DXA)

نویسندگان

  • Ranjitha Katikaneni
  • Adharsh Ponnapakkam
  • Eric Miller
  • Tulasi Ponnapakkam
  • Robert C. Gensure
چکیده

Dual Energy X-ray Absorptiometry (DXA) is effective in measuring bone mineral density (BMD) in mice for early detection of osteoporosis. However, scanners designed for use with small animals (i.e. PIXImus) are very expensive. Used human DXA machines are cheaper to obtain, but analysis of scans from these instruments is operator-dependent. Obtaining reliable data depends on having a single operator analyze the scans in a blinded fashion. Scan quality is improved by excising the bone prior to scanning, which does not allow serial measurements. This study describes a novel method of analyzing lumbar spine BMD in mice using whole body DXA. This non-invasive technique has a high degree of precision and reproducibility, with good correlation between multiple observers. Inter-observer variability (0.063 +/- 0.00317 g/cm(2) [mean +/- SD], 5.05 [% coefficient of variation (CV)], repeat scan variability (0.063 +/- 0.00364 g/cm(2) [mean +/- SD], 5.94 [%CV]) were very low compared to variability between different animals (0.063 +/- 0.00588 g/cm(2) [mean +/- SD], 9.64 [%CV]) and variability seen in same animal over time (0.011 +/- 0.00885 g/cm(2) [mean +/- SD], 80.68 [%CV]). The measurement error is thus smaller than the biological variation. Accuracy was determined by comparing average peak BMD from two scans per mouse in-vivo (0.066 g/cm(2)) versus excised spine (0.065 g/cm(2)). Furthermore, correlation between bone ash weights and whole body lumbar spine BMD measurements (p < 0.0001) was highly significant. This technique thus shows a high degree of precision and accuracy, even with multiple observers, for measuring BMD in mice using a DXA machine designed for clinical use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

Assessment of bone mineral density with dual energy X-ray absorptiometry in pre- and post-menopausal women

Background: Osteoporosis is a chronic disease that contributes substantially to decrease physical activity and decline in the quality of life. Osteoporosis can be diagnosed easily with the use of dual-energy X-ray absorptiometry (DXA) equipment. The aim of this study was to investigate the magnitude of bone loss on proximal femur and lumbar spine LS in pre- and post-menopausal women f...

متن کامل

Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis

Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...

متن کامل

The Correlation between Trabecular Bone Score and Lumbar Spine Bone Mineral Density in Patients with Normal and High Body Mass Index

Background: Trabecular bone score (TBS) measures the underlying quality of bone texture using dual-energy X-ray absorptiometry (DXA) images. The present study aimed to investigate the correlation between lumbar spine bone mineral density (BMD) and TBS, and subsequently determine whether the association varies with the body mass index (BMI). Methods: Data from 548 patients were collected a...

متن کامل

The Measurement of Bone Mineral Density of Bilateral Proximal Humerus - Using DXA in Korean Patients with Unilateral Rotator Cuff Tear -

INTRODUCTION Osteopenic or osteoporotic bone changes of proximal humerus may cause fracture or pull out of suture anchors during rotator cuff repair surgery[1], thereby compromising the success of repair. Dual energy X-ray absorptiometry (DXA) is the most popular technique to measure the general bone mineral density (BMD), especially at the hip and lumbar spine. However, there is wide variation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2009