Severe metallosis leading to femoral head perforation.

نویسندگان

  • Om Prakash Sharma
  • Jasjit Lochab
  • Yaron Berkovich
  • Oleg A Safir
  • Allan E Gross
چکیده

This article describes a case of severe metallosis in a 67-year-old woman who initially underwent primary total hip arthroplasty with a ceramic-on-ceramic articular bearing. This was subsequently revised to a metal-on-polyethylene articulation due to ceramic liner fracture. She presented with severe hip pain and a pelvic mass. Infective workup was negative. Perforation of the cobalt-chrome femoral head was observed intraoperatively. In addition, signs of extensive metallosis, including embedded ceramic debris from the primary procedure, were observed. To the authors' knowledge, this is the first report of a ceramic fracture that led to cobalt-chrome femoral head perforation after subsequent revision total hip arthroplasty. The patient underwent successful revision surgery with a ceramic-on-ceramic coupling. Ceramic materials are increasingly being used in total hip arthroplasty in younger patients. They have excellent tribological properties. However, they also have a lower elasticity and plasticity, which makes them susceptible to sudden material failure. Ceramic fracture is an uncommon yet problematic complication of total hip arthroplasty. Previous authors have reported the importance of performing thorough synovectomy following ceramic liner fracture. Revision surgery using couplings that have a lower hardness, such as metal-on-polyethylene, are best avoided due to their susceptibility to undergo abrasive wear from remaining ceramic particles. The authors advocate revision with ceramic-on-ceramic couplings after ceramic liner fracture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Severe metallosis following oxidised zirconium wear in total hip arthroplasty.

To cite: Gkouliopoulou E, Agathangelidis F, Vampertzis T, et al. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2016218025 DESCRIPTION We present a case of a man aged 81 years who underwent a primary cementless total hip arthroplasty. Eight years after the index surgery, failure of the arthroplasty was revealed by the presence of the radiographic ‘cloud sign’ (fi...

متن کامل

Metallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component

The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a m...

متن کامل

Metallosis in revision total elbow arthroplasty. Complications and staging method.

Although total elbow arthroplasty is a reliable treatment method for the arthritic joint, revision is necessary if loosening, instability, wear, fracture or infection occurs. We report 12 patients with 19 months (10-29) follow-up after revision arthroplasty for painful loosening in six cases, periprosthetic fracture in three, gross instability in one and skin perforation with possible infection...

متن کامل

Metallosis of the Resurfaced Hip

Metallosis of the hip is usually defined as aseptic fibrosis, local necrosis, or loosening of the prosthesis secondary to metallic corrosion and release of wear debris.8 It has also been defined as gray discoloration of the tissues of the joint, pain, an effusion, and elevated serum metal levels. Metallosis has been found with stainless steel, titanium, and cobalt chromium alloy femoral prosthe...

متن کامل

Extensive metallosis and necrosis in failed prostheses with cemented titanium-alloy stems and ceramic heads.

We describe three prostheses with cemented titanium-alloy stems and Al2O3 ceramic femoral heads which had to be revised after a mean period of implantation of 78 months. In each case, the neck of the prosthesis had been so severely worn that the profile was elliptical rather than circular. There was severe metallosis of the periprosthetic tissues. Metal particles isolated from the tissues were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 36 2  شماره 

صفحات  -

تاریخ انتشار 2013