The combined effects of sampling parameters on the sorbent tube sampling of phthalates in air
نویسندگان
چکیده
The adsorption properties of various sorbent materials were investigated to assess the factors affecting biases in the sorbent tube (ST) sampling of airborne phthalates. The recovery of phthalates was assessed critically in relation to four key sampling parameters: (1) three types of sorbent materials (quartz wool (QW), glass wool (GW), and quartz wool plus Tenax TA (QWTN)), (2) the concentration level of phthalate standards, (3) purge flow rate, and (4) purge volume for analysis based on a 'sorbent tube-thermal desorption-gas chromatography-mass spectrometry (ST-TD-GC-MS)' system. Among these parameters, the type of ST was the most influential in determining the recovery of phthalates. For a given ST type, the recovery of phthalates tends to improve with increases in the concentration level of standards. In case of QW and QWTN tubes, the breakthrough of phthalates was not observed up to the maximum purge volume (100 L) tested in this work; however, in case of GW, the recovery decreased drastically to 60% even at a purge volume of 1 L for low molecular weight phthalates. The results of our study demonstrate that accurate analysis of airborne phthalates can be achieved through proper control of key sampling parameters, particularly the choice of sorbent material.
منابع مشابه
کاربرد نمونه بردار تله سوزنی حاوی جاذب پلی دی متیل سیلوکسان جهت تعیین مقدار تترا کلرید کربن و تری کلرو اتیلن موجود در هوا
Introduction & Objective: The use of modern microextraction techniques for determination and evaluation of pollutants is progressively increasing nowadays. Needle trap microextraction (NTME) technique has privileges compared to the other techniques for sampling occupa-tional and environmental pollutants from air. In this study the application of NTD technique packed with polydimethylsiloxane ...
متن کاملField sampling method for quantifying odorants in humid environments.
Most air quality studies in agricultural environments use thermal desorption analysis for quantifying semivolatile organic compounds (SVOCs) associated with odor. The objective of this study was to develop a robust sampling technique for measuring SVOCs in humid environments. Test atmospheres were generated at ambient temperatures (23 +/- 1.5 degrees C) and 25, 50, and 80% relative humidity (RH...
متن کاملDetermining breakthrough of the soil fumigant chloropicrin from 120mg XAD-4 sorbent tubes
The emission to the atmosphere of soil fumigants such as chloropicrin represents a potentially important human exposure pathway. Commonly, determining the air concentration of fumigants is carried out by pumping air through sorbent tubes which chemically retain the fumigant. In order to obtain an accurate measurement, it is essential that the fumigant does not break through the sorbent tubes, s...
متن کاملارزیابی عملکرد ریز نمونه بردار تله سوزنی حاوی جاذب کامپوزیت سیلیکاته نانولوله کربنی جهت نمونه برداری از پرکلرواتیلن : مطالعه آزمایشگاهی و میدانی
Background and aims: Needle trap micro-sampler, with all advantages of microextraction techniques such as solid phase microextraction, owing to the ease of use and becoming a powerful method for air pollution monitoring. In this study, the performance of needle trap micro-sampler device with silica composite of carbon nanotubes, prepared using sol-gel technique, was investigated for health moni...
متن کاملRecent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review
Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...