Magnetic resonance whole body imaging at 3 Tesla: feasibility and findings in a cohort of asymptomatic medical doctors.

نویسندگان

  • Gladys G Lo
  • Victor Ai
  • K M Au-Yeung
  • John K F Chan
  • K W Li
  • Daisy Chien
چکیده

OBJECTIVES To evaluate the feasibility of whole body imaging using a 3 Tesla magnetic resonance scanner without a contrast agent, and to study the prevalence of abnormal findings among a cohort of asymptomatic doctors. DESIGN Prospective study. SETTING Private hospital, Hong Kong. PARTICIPANTS A total of 132 asymptomatic medical doctors (111 men, 21 women), with a mean age of 56 (range, 38-82) years, volunteered for the study. They underwent corresponding whole body imaging at our hospital between October 2005 and February 2006. Imaging involved a 3 Tesla magnetic resonance scanner with 32 channels, parallel imaging, Total Imaging Matrix technology, a maximum gradient amplitude of 40 mT/m and a slew rate of 200 mT/m/ms (Magnetom Tim Trio, Siemens Medical Solution, Erlangen, Germany). The use of matrix coils enabled coverage of the whole body. No contrast agent was used. MAIN OUTCOME MEASURES Detection of abnormalities in asymptomatic, apparently healthy adults. RESULTS All examinations were completed successfully. The mean scan time per subject was 33 (standard deviation, 4) minutes. All subjects tolerated the examination well and overall imaging quality was satisfactory. A total of 124 (94%) subjects had positive findings, of whom 24 (18%) had further workup. Five (4%) subjects were found to have tumours, of which two (1.5%) were proven malignant. Our cancer detection rate was comparable to that of other reported whole body screening studies using contrast magnetic resonance imaging and positron emission tomography. CONCLUSION We demonstrated the feasibility of performing whole body imaging in 30 minutes, using 32-channel magnetic resonance imaging at 3 Tesla without a contrast agent or any ionising radiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

متن کامل

Sexual Dimorphism in Volume of the Cerebral Hemispheres and Lateral Ventricles in Schizophrenia Using Magnetic Resonance Imaging

Purpose: This study is designed to determine the sexual dimorphism pattern in volume of the cerebral hemispheres and lateral ventricles in schizophrenia using magnetic resonance imaging (MRI) and to compare it with normal sexual dimorphism pattern in healthy brains. Materials and Methods: This study is performed on 29 healthy volunteers (21 males, 8 females) and 29 patients suffered from schiz...

متن کامل

A New Potential Contrast Agent for Magnetic Resonance Imaging: Iron Oxide-4A Nanocomposite

Background: Magnetic resonance imaging (MRI) contrast agents have an important role to differentiate healthy and diseased tissues. Access and design new contrast agents for the optimal use of MRI are necessary. This study aims to evaluate iron oxide–4A nanocomposite ability to act as a magnetic resonance imaging contrast agent.Materials and Methods: Iron oxide–4A nanocomposite (F4A) was syn...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hong Kong medical journal = Xianggang yi xue za zhi

دوره 14 2  شماره 

صفحات  -

تاریخ انتشار 2008