Minimum infective dose of HIV for parenteral dosimetry.
نویسندگان
چکیده
The probability of HIV-1 transmission in a small blood exposure such as a needlestick injury or an unsafe medical injection has been estimated indirectly. Now that several comparable laboratory simulations have provided data on inoculum volumes for such exposures, the epidemiological evidence supporting these estimates can be validated and qualified using dosimetry. This review of data on infective titre, viral load and injection inoculum volume compares three approaches to HIV dosimetry. Agreement across the three approaches indicates that unsafe medical injections are several times more likely to transmit HIV-1 than needlestick accidents, and that the risk remains substantial if injection equipment is wiped, rinsed or flushed prior to re-use. The 50% infective dose of HIV in blood exposures ranges from one virion (two copies RNA) in primary infection with CCR5 co-receptor using strains of HIV-1 to 65,000 copies HIV-1 RNA in blood from an asymptomatic source patient. The median transmission risks for unsafe intravenous or intramuscular injections using equipment cleaned but not sterilized after use on a symptomatic pre-AIDS patient are 1.8% (95% confidence interval [CI] 0.1-3.2%) and 0.8% (95% CI 0.1-1.4%), respectively.
منابع مشابه
Skin Dosimetry of Some Beta Sources using the VARSKIN2 Code
Introduction: Skin dose and depth dose distribution of some beta sources that can contaminate skin or protective clothing covering the skin have been calculated using VARSKIN2. Materials and Methods: In this research, absorbed dose to skin and depth dose from the skin surface have been calculated for 90Sr/90Y, 147Pm, 32P beta emitter radioisotopes by using input parameters: activity of source, ...
متن کاملPatient absorbed dose comparison in CT and Stereoradiography (EOS) imaging during lower limb torsion evaluation using in-vivo and in-vitro dosimetry methods
Introduction: Accurate evaluation of femoral and tibial torsion is essential for children or adult with legs deformity, becuse incorrect legs morphogenesis can lead to pathological situation. CT scan is commonly used for the measurement of skeletal bone parameters. But, disability in imaging from standing and sitting posture and absorb dose of patients are deficits of this meth...
متن کاملEvaluation of Full scatter convolution algorithm based Treatment Planning System performance in the presence of inhomogeneities using three-dimensional film dosimetry
Introduction: Inclusion of inhomogeneities such as air-filled cavities in the head and neck treatment fields may result in potential dosimetric disagreement which was caused by electronic disequilibrium. Most of treatments planning systems (TPS) are not able to predict dose distribution of inhomogeneous regions accurately. EBT2 films are used frequently in radiotherapy quality ass...
متن کاملVerification of the Accuracy of the Delivered Dose in Pelvic and Breast Cancer Radiotherapy by in-vivo Semi-Conductor Dosimetry
Introduction: Delivering maximum dose to tumor and minimum dose to normal tissues is the most important goal in radiotherapy. According to ICRU, the maximum acceptable uncertainty in the delivered dose compared to the prescribed dose should be lower than 5%, and this is because of the relationship between absorbed dose, tumor control and normal tissue damage. Absorbed dose accuracy is investiga...
متن کاملComparison of EBT and EBT3 RadioChromic Film Usage in Parotid Cancer Radiotherapy
Background: EBT and EBT3 radioChromic films have been used in radiotherapy dosimetry for years.Objective: The aim of the current study is to compare EBT and EBT3 radioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer.Methods: Calibrations of EBT and EBT3 films were performed with identical setups using a 6 MV photon beam of a Siemens Primus linac. Skin dose was m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of STD & AIDS
دوره 20 12 شماره
صفحات -
تاریخ انتشار 2009