Single-photon emission computed tomography in a patient with ictal metamorphopsia

نویسندگان

  • KYOUNG HEO
  • YANG JE CHO
  • SEUNG-KOO LEE
  • SUN AH PARK
  • KYU-SIK KIM
  • BYUNG IN LEE
چکیده

Metamorphopsia is a type of visual illusion, which has been reported as a rare ictal manifestation. The patient presented with a simple partial status epilepticus characterised by continuous facial metamorphopsia, intermittently accompanied by elementary visual hallucinations or other types of visual illusions. Subtraction single-photon emission computed tomography images showed an increased perfusion in the ventrolateral aspect of the right temporo-occipital junction (middle and inferior occipital, and inferior temporal gyri). The result suggests that the anatomical substrate involved in the generation of ictal facial metamorphopsia is located in the visual association areas at the right temporo-occipital junction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increased ictal perfusion of the thalamus in paroxysmal kinesigenic dyskinesia.

The ictal and interictal cerebral blood flow (CBF) were evaluated in a patient with right unilateral short lasting paroxysmal kinesigenic dyskinesia, by means of single photon emission computed tomography (SPECT). The patient was a 6 year old boy with no family history. During an attack, increased CBF was seen in the left thalamus. Subtraction of interictal CBF from ictal CBF disclosed a promin...

متن کامل

Brain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review

Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...

متن کامل

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

Role of Single Photon Emission Computed Tomography in Epilepsy

Molecular imaging with ictal single photon emission computed tomography (SPECT) is an established functional imaging modality for the presurgical evaluation of patients with refractory partial onset seizures. SPECT coregistered on to the MRI has greater sensitivity to identify the ictal onset zone. Ictal SPECT should always be interpreted in the context of other presurgical investigations. Icta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Seizure

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2004