Detailed α - decay study of 180 Tl
نویسندگان
چکیده
منابع مشابه
Growth of CsI(Tl) crystals doped with Ca and Tm and investigation of its scintillation characteristics
In this work, the growth of CsI(Tl) crystals as gamma detector was performed using vertical Bridgman method with Ca and Tm co-dopants. For evaluation of the growth crystals, X-Ray Diffraction (XRD), photoluminescence and thermoluminescence spectra as well as recorded gamma spectra were employed. In addition, the scintillation properties including energy resolution, scintillation decay time, abs...
متن کاملA DETAILED STUDY TOWARD THE NANO -CRYSTALLIZATION OF α – Fe IN Fe55-X Cr18Mo7B16C4 BULK AMORPHOUS ALLOY
Crystallization of α – Fe phase during annealing process of Fe55Cr18Mo7B16C4 bulk amorphous alloy has been evaluated by X- ray diffraction, differential scanning calorimetric tests and TEM observations in this research. In effect, crystallization mechanism and activation energy of crystallization were evaluated using DSC tests in four different heating rates (10, 20, 30, 40 K/min). A two -st...
متن کاملNuclear Data Evaluation for Mass Chain A=217:Odd-Proton Nuclei
Thallium (81(217)Tl, Bismuth (83(217)Bi), Astatine (85(217)At), Francium (87(217)Fr), Actinium (89(217)Ac) and Protactinium (91(217)Pa) are of odd-proton numbers among the mass chain A = 217. In the present work, the half-lives and gamma transitions for the six nuclei have been studied and adopted based on the recently published interactions or unevaluated nuclear data sets XUNDL. The Q (α) has...
متن کاملScintillating double beta decay bolometers
P. Gorla Laboratori Nazionali del Gran Sasso, I-67010, Assergi (L’Aquila), Italy Abstract We present the results obtained in the development of scintillating Double Beta Decay bolometers. Several Mo and Cd based crystals were tested with the bolometric technique. The scintillation light was measured through a second independent bolometer. A 140 g CdWO4 crystal was run in a 417 h live time measu...
متن کاملEnergy window setting for optimum Tl-201 cardiac imaging [Persian]
Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017