Validation of an alternative device for volumetric quantification of crevicular fluid.

نویسندگان

  • Fernanda G Alencar
  • Giulia C Kronbauer
  • Sabrina C Gomes
چکیده

The volume of crevicular fluid is directly proportional to the degree ofperiodontal inflammation. The Periopaper system, with readings taken using the Periotron, has gained wide acceptance in the literature for measuring this volume. Alternative methods have also been proposed. This study investigated an alternative device for measuring the volume and compared it to the readings taken in Periotron Units (PU). Strips of absorbent paper (PS) of the same size as Periopapers (P) were obtained. Next, previously defined volumes were quantified in PU (R1: P and R2: PS) and also in millimeters (T1: P; T2: PS) using an alternative reading method (ruler and magnifying glass). The mean measurements for each volume were compared (Student's t test) and no difference was detected between them in PU (R1=66.8 and R2=72.5) or in millimeters (T1=2.83 and T2=2.96). The degree of correlation between groups was evaluated using Pearson's coefficient, with an intragroup r of 0.98 (R1xT1; R2xT2; R1xT2). Linear regression coefficients were also calculated, finding R1xT1=23.5; R2xT2=26.5 and R1xT2=23.3. The method's reproducibility was verified using intraclass correlation coefficients, with excellent results--all above 0.96. This being so, it was concluded that it is possible to measure the volume collected in millimeters, with a high degree of reproducibility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative volumetric and clinical evaluation of peri-implant sulcular fluid and gingival crevicular fluid

PURPOSE Peri-implant sulcular fluid (PISF) has a production mechanism similar to gingival crevicular fluid (GCF). However, limited research has been performed comparing their behavior in response to inflammation. Hence, the aim of the present study was to comparatively evaluate PISF and GCF volume with varying degrees of clinical inflammatory parameters. METHODS Screening of patients was cond...

متن کامل

The HPLC assay of concentration of azithromycin from two different manufacturers in gingival crevicular fluid (GCF)

Background: Azithromycin (AZM) is used in periodontal infections. The present study compared gingival crevicular fluid concentration of azithromycin of two pharmaceutical companies through the HPLC method. Methods: Two groups (n=15) of healthy volunteers participated in this study. The first group received an imported azithromycin (ImAZM) tablet (250 mg, PO) and the second group received an ...

متن کامل

Receptor Activator of Nuclear Factor Kappa B Ligand (RANKL) Levels in Peri-Implant Crevicular Fluid

Background: Receptor activator of nuclear factor kappa B ligand (RANKL) is one of the key cytokines in the induction of osteoclastogenesis both in vitro and in vivo.Several reports indicated the presence of sRANKL in gingival crevicular fluid of patients with periodontal diseases. Objective: To determine the presence of RANKL in peri-implant crevicular fluid samples of implants with peri-implan...

متن کامل

Development and validation of RP HPLC method for determination of betamethasone dipropionate in gingival crevicular fluid.

Abstract A simple RP HPLC method for quantification of betamethasone dipropionate (BDP) in gingival crevicular fluid (GCF) has been developed and validated. GCF represents a valuable matrix for therapeutic monitoring of drugs used in the treatment of periodontal disease. The proposed method involves single step extraction for sample preparation. The calibration curve for BDP was linear over the...

متن کامل

Identification of Gingival Crevicular Fluid Sampling, Analytical Methods, and Oral Biomarkers for the Diagnosis and Monitoring of Periodontal Diseases: A Systematic Review

Background. Several studies in the last decades have focused on finding a precise method for the diagnosis of periodontal disease in its early stages. Aim. To evaluate from current scientific literature the most common and precise method for gingival crevicular fluid (GCF) sample collection, biomarker analytical methods, and the variability of biomarker quantification, even when using the same ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta odontologica latinoamericana : AOL

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2011