Three-dimensional finite element analysis of immediate loading mini over denture implants with and without acrylonitrile O-ring.

نویسندگان

  • Srinivasan Jayaraman
  • Sreekanth Mallan
  • Babu Rajan
  • Murugan Pazhaniappan Anachaperumal
چکیده

AIM OF THE STUDY The aim of the study was to check the stress absorbed by the bone around mini over-denture dental implant with and without acrylonitrile O-ring under two different loading conditions. The initial stress absorbed by the implant plays a significant role in the success of the immediate loading implants. MATERIALS AND METHODS A three-dimensional finite element analysis using Pro-E mechanical finite element software was used to check the stress absorbed by the bone with and without acrylonitrile O-ring. The implant and the mandible where modeled from the data obtained from C.T. scan and optical projector using reverse engineering process. Two different loading conditions of 80 N and 220 N were determined and the analysis was done. RESULTS The result showed at lower loads (80 N), there was not much difference in the stress absorbed by the cancellous bone with or without acrylonitrile O-ring, but at higher loads (220), there was difference in the stress absorbed by the cancellous bone with (0.03508 Mpa) and without acrylonitrile O-ring (3.874 Mpa) which showed that significant stress was absorbed by the acrylonitrile O-ring. CONCLUSION This study proves that higher loads during parafunctional movement were absorbed by the acrylonitrile O-ring increasing the success of the implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...

متن کامل

Mechanical Buckling Analysis of Composite Annular Sector Plate with Bean-Shaped Cut-Out using Three Dimensional Finite Element Method

In this paper, mechanical buckling analysis of composite annular sector plates with bean shape cut out is studied. Composite material sector plate made of Glass-Epoxy and Graphite-Epoxy with eight layers with same thickness but different fiber angles for each layer. Mechanical loading to form of uniform pressure loading in radial, environmental and biaxial directions is assumed. The method used...

متن کامل

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

Effect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis

This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...

متن کامل

Stress distribution patterns of implant supported overdentures-analog versus finite element analysis: A comparative in-vitro study

AIMS AND OBJECTIVES The aim of this study was to asses & compare the load transfer characteristics of Ball/O-ring and Bar/Clip attachment systems in implant supported overdentures using analog and finite element analysis models. METHODOLOGY For the analog part of the study, castable bar was used for the bar and clip attachment and a metallic housing with a rubber O-ring component was used for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indian journal of dental research : official publication of Indian Society for Dental Research

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2012