Can modern infrared analyzers replace gas chromatography to measure anesthetic vapor concentrations?
نویسندگان
چکیده
BACKGROUND Gas chromatography (GC) has often been considered the most accurate method to measure the concentration of inhaled anesthetic vapors. However, infrared (IR) gas analysis has become the clinically preferred monitoring technique because it provides continuous data, is less expensive and more practical, and is readily available. We examined the accuracy of a modern IR analyzer (M-CAiOV compact gas IR analyzer (General Electric, Helsinki, Finland) by comparing its performance with GC. METHODS To examine linearity, we analyzed 3 different concentrations of 3 different agents in O₂: 0.3, 0.7, and 1.2% isoflurane; 0.5, 1, and 2% sevoflurane; and 1, 3, and 6% desflurane. To examine the effect of carrier gas composition, we prepared mixtures of 1% isoflurane, 1 or 2% sevoflurane, or 6% desflurane in 100% O₂ (= O₂ group); 30%O₂+ 70%N₂O (= N₂O group), 28%O₂ + 66%N₂O + 5%CO₂ (= CO₂ group), or air. To examine consistency between analyzers, four different M-CAiOV analyzers were tested. RESULTS The IR analyzer response in O2 is linear over the concentration range studied: IR isoflurane % = -0.0256 + (1.006 * GC %), R = 0.998; IR sevoflurane % = -0.008 + (0.946 * GC %), R = 0.993; and IR desflurane % = 0.256 + (0.919 * GC %), R = 0.998. The deviation from GC calculated as (100*(IR-GC)/GC), in %) ranged from -11 to 11% for the medium and higher concentrations, and from -20 to +20% for the lowest concentrations. No carrier gas effect could be detected. Individual modules differed in their accuracy (p = 0.004), with differences between analyzers mounting up to 12% of the medium and highest concentrations and up to 25% of the lowest agent concentrations. CONCLUSION M-CAiOV compact gas IR analyzers are well compensated for carrier gas cross-sensitivity and are linear over the range of concentrations studied. IR and GC cannot be used interchangeably, because the deviations between GC and IR mount up to ± 20%, and because individual analyzers differ unpredictably in their performance.
منابع مشابه
Solubility of haloether anesthetics in human and animal blood.
BACKGROUND Anesthetic blood solubility predicts pharmacokinetics for inhaled agents and is essential for determination of blood anesthetic concentrations from end-tidal gas concentrations using Henry's Law. Though used to model anesthetic effects in humans, there are limited interspecies solubility comparisons that include modern haloethers. This study aimed to measure hematocrit-adjusted blood...
متن کاملMeasurement of nitrous oxide concentrations from Wisconsin dairy barns
Abstract. Nitrous oxide (N2O) is one of the important greenhouse gases. N2O emissions from anthropogenic sources are approximately 7-8 million tones N/yr worldwide and 70% of these emissions are caused by crop and animal production. In this study, direct N2O production from dairy cattle (enteric fermentation) and feces/urine temporarily stored in two freestall dairy barns were measured with 1) ...
متن کاملPredictive accuracy of a model of volatile anesthetic uptake.
UNLABELLED A computer program that models anesthetic uptake and distribution has been in use in our department for 20 yr as a teaching tool. New anesthesia machines that electronically measure fresh gas flow rates and vaporizer settings allowed us to assess the performance of this model during clinical anesthesia. Gas flow, vaporizer settings, and end-tidal concentrations were collected from th...
متن کاملEffects of Temperature, Pressure and Water Vapor on Gas Phase Infrared Absorption by CO2
Full description of an absorption band is complex, but approximate expressions can be used over limited ranges of absorber mole fraction, pressure and pathlength. It can be shown that the “non-overlapping line approximation” applies at ambient pressure and CO2 mole fraction over the short pathlengths found in LI-COR infrared gas analyzers (Wolfe and Zissis, 1978). This leads to a “scaling law” ...
متن کاملUse of Multicomponent Infrared Gas Analyzers at Waste-to-Energy Facilities
Multicomponent Infrared Gas analyzers have been a workhorse as Continuous Emissions Monitoring Systems (CEMS) in the waste-to-energy (WTE) application for the past two decades. It is the technique of choice for many facilities. With obsolescence for electronics, instrumentation and data acquisition systems (DAS) averaging less than 10 years, the earlier multicomponent CEMS are being upgraded to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- BMC Anesthesiology
دوره 8 شماره
صفحات -
تاریخ انتشار 2008