Initial Accuracy of HIV Rapid Test Kits Stored in Suboptimal Conditions and Validity of Delayed Reading of Oral Fluid Tests

نویسندگان

  • Augustine T. Choko
  • Miriam Taegtmeyer
  • Peter MacPherson
  • Derek Cocker
  • McEwen Khundi
  • Deus Thindwa
  • Rodrick S. Sambakunsi
  • Moses K. Kumwenda
  • Kondwani Chiumya
  • Owen Malema
  • Simon D. Makombe
  • Emily L. Webb
  • Elizabeth L. Corbett
چکیده

OBJECTIVES To evaluate the effect of storing commonly used rapid diagnostic tests above manufacturer-recommended temperature (at 37°C), and the accuracy of delayed reading of oral fluid kits with relevance to HIV self-testing programmes. DESIGN A quality assurance study of OraQuick (OraSure), Determine HIV 1/2™ (Alere) and Uni-Gold™ (Recombigen®). METHODS Consecutive adults (≥18y) attending Ndirande Health Centre in urban Blantyre, Malawi in January to April 2012 underwent HIV testing with two of each of the three rapid diagnostic test kits stored for 28 days at either 18°C (optimally-stored) or at 37°C (pre-incubated). Used OraQuick test kits were stored in a laboratory for delayed day 1 and subsequent monthly re-reading was undertaken for one year. RESULTS Of 378 individuals who underwent parallel testing, 5 (1.3%) were dropped from the final analysis due to discordant or missing reference standard results (optimally-stored Determine and Uni-Gold). Compared to the diagnostic reference standard, OraQuick had a sensitivity of 97.2% (95% CI: 93.6-99.6). There were 7 false negative results among all test kits stored at 37°C and three false negatives among optimally stored kits. Excellent agreement between pre-incubated tests and optimally-stored tests with Kappa values of 1.00 for Determine and Uni-Gold; and 0.97 (95% CI: 0.95; 1.00) for OraQuick were observed. There was high visual stability on re-reading of OraQuick, with only 1/375 pre-incubated and 1/371 optimally-stored OraQuick kits changing from the initial result over 12 months. CONCLUSION Erroneous results observed during HIV testing in low income settings are likely to be due to factors other than suboptimal storage conditions. Re-reading returned OraQuick kits may offer a convenient and accurate quality assurance approach, including in HIV self-testing programmes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HIV Rapid Diagnostic Test Inventories in Zambézia Province, Mozambique: A Tale of 2 Test Kits

Background The first pillar of the UNAIDS 90-90-90 goal seeks to accurately identify persons living with HIV (PLHIV), a process that is predicated on facilities having the necessary HIV tests available to perform the task. In many rural settings, the identification of PLHIV is accomplished through a two-step process involving the sequential use of 2 separate rapid diagnostic tests (RDTs)....

متن کامل

False Positive Rate of Rapid Oral Fluid HIV Tests Increases as Kits Near Expiration Date

BACKGROUND Because a recent cluster of false positive results on the OraQuick ADVANCE Rapid HIV-1/2 Antibody Test occurred in San Francisco on test kits close to their expiration date, we decided to assess the relationship between time to expiration and rate of false positive results from tests used with oral fluid. METHODOLOGY/PRINCIPAL FINDINGS We analyzed results of 20,904 tests with eithe...

متن کامل

Field Evaluation of Calypte’s AWARE™ Blood Serum Plasma (BSP) and Oral Mucosal Transudate (OMT) Rapid Tests for Detecting Antibodies to HIV-1 and 2 in Plasma and Oral Fluid

As programs to prevent and care for HIV-infected persons are scaled-up in Africa, there is the need for continuous evaluation of the performance of test kits that could best support these programs. The present study evaluated the sensitivity, specificity, ease of use, and cost of AWARE Blood Serum Plasma (BSP) and Oral Mucosal Transudate (OMT) Rapid HIV-1/2 test kits using real-time and archive...

متن کامل

Evaluation of Diagnostic Accuracy, Feasibility and Client Preference for Rapid Oral Fluid-Based Diagnosis of HIV Infection in Rural India

BACKGROUND Oral fluid-based rapid tests are promising for improving HIV diagnosis and screening. However, recent reports from the United States of false-positive results with the oral OraQuick ADVANCE HIV1/2 test have raised concerns about their performance in routine practice. We report a field evaluation of the diagnostic accuracy, client preference, and feasibility for the oral fluid-based O...

متن کامل

Willingness to Use the Oral Fluid HIV Rapid Test among Men Who Have Sex with Men in Beijing, China

BACKGROUND Early detection of HIV infection enables timely care and treatment. However, many men who have sex with men (MSM) remain unaware of their HIV status because they do not or are unable to access HIV testing services. Oral fluid HIV rapid tests have the potential to increase HIV testing. This study is the first to evaluate willingness to use the oral fluid test among MSM in China. MET...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016