Diameters of the cavo-sinus-tricuspid area in relation to type I atrial flutter.

نویسندگان

  • Dariusz Kozłowski
  • Jolanta Hreczecha
  • Magdalena Skwarek
  • Grzegorz Piwko
  • Adam Kosiński
  • Marcin Gawrysiak
  • Marek Grzybiak
چکیده

Cardiac arrhythmias have troubled patients and fascinated physicians for centuries. The twentieth century was an era of progress, when the mechanism of cardiac disorders became more commonly recognised. Arrhythmias may be due to abnormalities of automaticity, to abnormalities of conduction, or to a combination of both. In order for re-entry to occur, an area of slowing conduction combined with unidirectional block must be present. Much investigation has centred on the underlying re-entry mechanisms of atrial flutter. In the light of these facts, it would seem that a close acquaintance with the detailed topography of the vena cava orifice (cavo), coronary sinus orifice (sinus) and the attachment of the septal leaflet of the tricuspid valve (tricupid) area could be of great interest, especially for invasive cardiologists. The research was conducted carried out on material consisting of 41 hearts of humans of both sexes from the age of 12 to 80 (6 female, 35 male). Classical macroscopic methods of anatomical evaluation were used. The following measurements were made: the shortest distance between the Eustachian valve and the attachment of the tricuspid valve on the left margin of the coronary sinus orifice (diameter 1), the distance between the attachment of the tricuspid valve and the inferior margin of the sinus orifice (diameter 2), the distance between the Eustachian valve and the attachment of the tricuspid valve on the right margin of the coronary sinus orifice (diameter 3), the distance between the inferior margin of the vena cava inferior and the attachment of the tricuspid valve (diameter 4) and, finally, the diameter between the attachment of the septal cusp of the tricuspid valve and the extemal border of the vena cava inferior (diameter 5). No correlation was found between the age and sex of the three groups of the material. The dimensions of the structure examined were similar in the three groups of hearts. In young adult hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.02 mm (diameter 1), 8.97 mm (diameter 2), 17.27 mm (diameter 3), 26.87 mm (diameter 4), 36.42 mm (diameter 5). In the mature adult hearts all the diameters measured ranged from 8 to 45 mm; 18.19 mm (diameter 1), 10.54 mm (diameter 2), 19.95 mm (diameter 3), 28.90 mm (diameter 4), 39.63 mm (diameter 5). In the older adults hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.65 mm (diameter 1), 8.70 mm (diameter 2), 7.25 mm (diameter 3), 26.80 mm (diameter 4), 35.85 mm (diameter 5). On the basis of our study we were able to conclude that the diameters of the cavo-sinus-tricuspid area were constant and did not differ significantly within the three (young, mature, old) adult groups examined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Improvement of the Atrial Flutter Rhythm upon the Removal of the Infected Permanent Pacemaker Lead

Pacemaker infection has multiple risk factors. Its presentation is most often similar to infected endocarditis and the diagnosis is made through studying blood cultures. Transesophageal echocardiography can confirm the diagnosis. The most common microorganisms are staphylococcus speciesis. As a matter of fact, complete pacemaker removal appears to be the only definite treatment. We presented a ...

متن کامل

Arrhythmias in Patients With Pulmonary Hypertension; A Narrative Review of the Current Literature

Incidence and prognostic relevance of supraventricular arrhythmias were evaluated in nine studies. These studies investigated patients with different forms of pulmonary hypertension. Supraventricular arrhythmias were more often found in patients with group two pulmonary hypertension. Common findings in these patients were elevated right atrial pressure and diameters and reduced tricuspid annula...

متن کامل

Voltage-directed cavo-tricuspid isthmus ablation using a novel ablation catheter mapping technology in a myotonic dystrophy type I patient

A successful case of maximum voltage-directed cavo-tricuspid isthmus (CTI) ablation using a novel ablation catheter mapping technology in a myotonic dystrophy type I (DM1) patient is reported. The patient complained recurrent episodes of atrial flutter, revealed by the atrio-ventricular electrograms analysis during the routine pacemaker controls.

متن کامل

Spontaneous Demonstration Of Counterclockwise Right Atrial Activation Following Successful Isthmus Ablation

We describe an uncommon case of typical flutter with symptomatic sinus node dysfunction, in which a permanent junctional rhythm developed following ablation of the cavo-tricuspid isthmus. This rhythm activated the right atrium in counter clockwise manner thus providing spontaneous proof of unidirectional isthmus block, a phenomenon that is usually demonstrated by proximal coronary sinus pacing.

متن کامل

Can Right Ventricular Pacing be Useful in the Assessment of Cavo-tricuspid Isthumus Block?

BACKGROUND Cavo-tricuspid isthmus (CTI) block is currently assessed by coronary sinus (CS) pacing or low lateral and septal atrial pacing. Occasionally, CS catheterization through the femoral route can be difficult to perform or right atrial pacing can be problematic because of catheter instability or saturation of the atrial electrograms recorded near the catheter. OBJECTIVES Our aim was to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Folia morphologica

دوره 62 2  شماره 

صفحات  -

تاریخ انتشار 2003