Adult patient doses in interventional neuroradiology.
نویسندگان
چکیده
We investigated radiation doses to 149 adult patients who underwent interventional neuroradiologic procedures, consisting of 132 patients who had diagnostic imaging examinations and 17 patients who had therapeutic procedures. The interventional procedures were carried out on a biplane system capable of performing fluoroscopy and digital subtraction angiography (DSA). The x-ray imaging system was interfaced to a patient dosimetry system, which computed surface (skin) doses based on the selected radiographic technique factors in each of the radiographic and fluoroscopic imaging modes. For each patient, an assessment was made of the maximum surface dose received during the procedure, which predicts the possibility of inducing deterministic effects. Knowledge of the surface doses, beam quality and x-ray cross sectional area permitted the computation of the total energy imparted to each patient. Energy imparted values were converted to effective dose, which provides an estimate of the stochastic radiation risk to the patient. The median surface dose for the frontal plane during diagnostic imaging examinations was 1.3 Gy, with a maximum surface dose of 5.1 Gy. The median surface dose for the frontal plane during therapeutic procedures was 2.8 Gy with a maximum surface dose of 5.0 Gy. Ratios of the lateral to frontal median surface doses were 0.47 for diagnostic examinations and 0.68 for interventional procedures. The median energy imparted was 1.8 J during fluoroscopy, and 4.3 J during radiography, showing that on average, 66% of the patient exposure comes from radiographic imaging (DSA). For diagnostic examinations, the median patient effective dose was 33 mSv, with a maximum of 152 mSv. For therapeutic procedures, the median patient effective dose was 74 mSv, with a maximum of 156 mSv. In interventional neuroradiology, surface doses could induce deterministic effects, and the corresponding effective doses are noticeably higher than those normally encountered in diagnostic radiology.
منابع مشابه
Brain radiation doses to patients in an interventional neuroradiology laboratory.
BACKGROUND AND PURPOSE In 2011, the International Commission on Radiologic Protection established an absorbed-dose threshold to the brain of 0.5 Gy as likely to produce cerebrovascular disease. In this paper, the authors investigated the brain doses delivered to patients during clinical neuroradiology procedures in a university hospital. MATERIALS AND METHODS The radiation dose delivered to t...
متن کاملPATIENT SAFETY Patient Radiation DoseManagement in the Follow-Up of Potential Skin Injuries in Neuroradiology
BACKGROUND AND PURPOSE: Radiation exposure from neurointerventional procedures can be substantial, with risk of radiation injuries. We present the results of a follow-up program applied to potential skin injuries in interventional neuroradiology based on North American and European guidelines. MATERIALS ANDMETHODS: The following guidelines approved in 2009 by SIR and CIRSE have been used over t...
متن کاملRadiation Doses in Patient Eye Lenses during Interventional Neuroradiology Procedures.
BACKGROUND AND PURPOSE Eye lenses are among the most sensitive organs to x-ray radiation and may be considered at risk during neurointerventional radiology procedures. The threshold dose to produce eye lens opacities has been recently reduced to 500 mGy by the International Commission on Radiologic Protection. In this article, the authors investigated the radiation doses delivered to patients' ...
متن کاملAssessment of patient entrance skin dose (ESD) and effective dose (ED) for the most common interventional radiological exams at Mazandaran hospital
Introduction: Nowadays we are witnessing an exponential application of interventional radiology techniques in various communities as well as Iran. Radiological technique is regarded as the 2nd contributing factor in increasing the amount of public doses in various societies. So that related radiation protection organization has recommended measuring patient d...
متن کاملRadiation doses to patients in neurointerventional procedures.
PURPOSE To evaluate stochastic and deterministic risks associated with neurointerventional procedures for the patient. METHODS Eight neurovascular interventional procedures were evaluated to determine the entrance skin dose and effective dose for the patient. Dosimetry was done with thermoluminescence dosimeters. The highest dose on the patient's head was recorded as the maximum entrance skin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 29 5 شماره
صفحات -
تاریخ انتشار 2002