Hemocompatibility evaluation of poly(diol citrate) in vitro for vascular tissue engineering.
نویسندگان
چکیده
One of the ongoing challenges in tissue engineering is the synthesis of a hemocompatible vascular graft. Specifically, the material used in the construct should have antithrombogenic properties and support the growth of vascular cells. Our laboratory has designed a novel biodegradable, elastomeric copolymer, poly(1,8-octanediol citrate) (POC), with mechanical and degradation properties suitable for vascular tissue engineering. The hemocompatibility of POC in vitro and its ability to support the attachment and differentiation of human aortic endothelial cell (HAEC) was assessed. The thrombogenicity and inflammatory potential of POC were assessed relative to poly(l-lactide-co-glycolide) and expanded poly(tetrafluoroethylene), as they have been used in FDA-approved devices for blood contact. Specifically, platelet aggregation and activation, protein adsorption, plasma clotting, and hemolysis were investigated. To assess the inflammatory potential of POC, the release of IL-1beta and TNF-alpha from THP-1 cells was measured. The cell compatibility of POC was assessed by confirming HAEC differentiation and attachment under flow conditions. POC exhibited decreased platelet adhesion and clotting relative to control materials. Hemolysis was negligible and protein adsorption was comparable to reference materials. IL-1beta and TNF-alpha release from THP-1 cells was comparable among all materials tested, suggesting minimal inflammatory potential. POC supported HAEC differentiation and attachment without any premodification of the surface. The results described herein are encouraging and suggest that POC is hemocompatible and an adequate candidate biomaterial for in vivo vascular tissue engineering.
منابع مشابه
Synthesis and evaluation of poly(diol citrate) biodegradable elastomers.
Herein, we report the synthesis and evaluation of a novel family of biodegradable and elastomeric polyesters, poly(diol citrates). Poly(diol citrates) were synthesized by reacting citric acid with various diols to form a covalent cross-linked network via a polycondensation reaction without using exogenous catalysts. The tensile strength of poly(diol citrates) were as high as 11.15+/-2.62 MPa an...
متن کاملPoly(diol citrate) nanocomposites with enhanced mechanical properties
The mechanical properties of a tissue engineering scaffold are particularly important when engineering soft tissues as it has been shown that mechanical stimulation during in vitro tissue development can modulate cell differentiation, increase extracellular matrix synthesis, and enhance the mechanical properties of cartilaginous, ligamentous, and smooth muscle containing tissues [1-5]. Unfortun...
متن کاملبررسی خون سازگاری سطح مزانشیمی پردهی آمنیون انسانی در مقایسه با رگ مصنوعی پوشش داده شده با هپارین
Background and Objective: Amniotic membrane (AM) as a natural tissue has lots of unique features which make it a suitable candidate for vascular tissue engineering. The aim of this study was to evaluate blood compatibility of mesenchymal surface of the AM. Materials and Methods: In this study, the effect of mesenchymal surface of the AM on internal and external coagulation pathways, hemolysis a...
متن کاملNovel biphasic elastomeric scaffold for small-diameter blood vessel tissue engineering.
Compliance mismatch, thrombosis, and long culture times in vitro remain important challenges to the clinical implementation of a tissue-engineered small-diameter blood vessel (SDBV). To address these issues, we are developing an implantable elastomeric and biodegradable biphasic tubular scaffold. The scaffold design uses connected nonporous and porous phases as a basis to mimic, respectively, t...
متن کاملIn vitro hemocompatibility evaluation of poly (4-hydroxybutyrate) scaffold.
The biosynthetic thermoplastic poly-4-hydroxybutyrate (P4HB) possesses favorable tensile strength and elongation performance and has been studied as a new implantable polymer material for medical uses. However, its hemocompatibility has not been tested to confirm its applicability to tissue engineering. In this study, a series of experiments was performed that included erythrocyte hemolysis tes...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical materials research. Part A
دوره 82 4 شماره
صفحات -
تاریخ انتشار 2007