Keratometry device for surgical support

نویسندگان

  • Liliane Ventura
  • Jean-Jacques De Groote
  • Paula Saia
  • Sidney J Faria e Sousa
چکیده

BACKGROUND High astigmatisms are usually induced during corneal suturing subsequent to tissue transplantation or any other surgery which involves corneal suturing. One of the reasons is that the procedure is intimately dependent on the surgeon's skill for suturing identical stitches. In order to evaluate the influence of the irregularity on suturing for the residual astigmatism, a prototype for ophthalmic surgical support has been developed. The final intention of this prototype is to be an evaluation tool for guided suture and as an outcome diminish the postoperative astigmatism. METHODS The system consists of hand held ring with 36 infrared LEDs, that is to be projected onto the lachrymal film of the cornea. The image is reflected back through the optics of the ocular microscope and its distortion from the original circular shape is evaluated by developed software. It provides keratometric and circularity measurements during surgery in order to guide the surgeon for uniformity in suturing. RESULTS The system is able to provide up to 23D of astigmatism (32D - 55D range) and is +/- 0.25D accurate. It has been tested in 14 volunteer patients intraoperative and has been compared to a commercial keratometer Nidek Oculus Hand-held corneal topographer. The correlation factors are 0.92 for the astigmatism and 0.97 for the associated axis. CONCLUSION The system is potentially efficient for guiding the surgeon on uniformity of suturing, presenting preliminary data indicating an important decrease on the residual astigmatism, from an average of 8D - for patients not submitted to the prototype guidance - to 1.4D - for patients who have actually been submitted to the prototype guidance - after the first 24 hours post-surgery and in the subsequent weeks. It also indicates that the surgeon should achieve circularity greater or equal to 98% in order to avoid postoperative astigmatisms over 1D. TRIAL REGISTRATION TRIAL REGISTRATION NUMBER CAAE - 0212.0.004.000-09.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Evaluation of biometry and corneal astigmatism in cataract surgery patients from Central China

BACKGROUND To evaluate the distribution of biometric parameters and corneal astigmatism using the IOLMaster device before phacoemulsification in cataract patients in Central China. METHODS Consecutive cataract patients were recruited at the Central Hospital of Wuhan between January 2015 and June 2016. Ocular axial length (AL), keratometry values, anterior chamber depth (ACD) and horizontal co...

متن کامل

Prospective study of toric IOL outcomes based on the Lenstar LS 900® dual zone automated keratometer

BACKGROUND To establish clinical expectations when using the Lenstar LS 900® dual-zone automated keratometer for surgery planning of toric intraocular lenses. METHODS Fifty eyes were measured with the Lenstar LS 900® dual-zone automated keratometer . Surgical planning was performed with the data from this device and the known surgically induced astigmatism of the surgeon. Post-operative refra...

متن کامل

Urgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series

Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...

متن کامل

Effect of keratometry on visual outcomes 1 month after hyperopic LASIK.

PURPOSE To determine whether preoperative, postoperative, or change in keratometry can be used to predict visual outcomes in hyperopic LASIK. METHODS A retrospective analysis was conducted on hyperopic eyes treated at Optical Express clinics. All eyes were targeted for emmetropia and treated using wavefront-guided LASIK (VISX S4, Abbott Medical Optics [AMO]), with flaps created using a femtos...

متن کامل

Keratometry in eyes with bilateral pediatric cataract at tertiary eye care center in Nepal: a preliminary report.

Pre-operative keratometry measurement of the subjects was done in 80 children with bilateral congenital cataract below 15 years who had undergone pediatric cataract surgery. The objective of the study was to evaluate the average keratometry reading in Nepalese children with bilateral cataract. The keratometry reading was taken under general anesthesia with the Nidek Auto Keratometer, model KM-5...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2009