Improvement of treatment plans developed with intensity-modulated radiation therapy for concave-shaped head and neck tumors.

نویسندگان

  • Nesrin Dogan
  • Leonid B Leybovich
  • Stephanie King
  • Anil Sethi
  • Bahman Emami
چکیده

PURPOSE To improve dose conformity and normal tissue sparing in patients with concave-shaped head and neck cancers by using tomotherapy and static step-and-shoot intensity-modulated radiation therapy (IMRT) and by comparing results with those of three-dimensional (3D) conformal radiation therapy (CRT) and two-dimensional (2D) radiation therapy. MATERIALS AND METHODS Treatment planning in 10 patients with concave-shaped head and neck tumors was performed by using tomotherapy and step-and-shoot IMRT, 3D CRT, and 2D techniques. IMRT plans were modified by placing "virtual critical structures" in regions outside the target where hot spots occurred. These modified plans were used for comparison because they provided better dose conformity. Critical structures were the spinal cord, the parotid glands, and the mandible. Comparisons were performed by means of dose-volume histograms, clinical target volume (CTV), target covered by 95% isodose (D(95%)), dose received by 5% of the critical structure volume (D(5%)), maximum dose, mean dose, and normal tissue complication probability for critical structures. RESULTS Original IMRT plans showed more conformal dose distributions than those in 3D CRT and 2D plans. However, hot spots developed in the posterior and anterior neck. Introduction of virtual critical structures in IMRT plans resulted in removal of these hot spots without affecting target coverage. Modified IMRT plans also demonstrated better CTV coverage than that in 3D CRT and 2D plans. The average D(95%) was 97.3% with tomotherapy, 97.1% with step-and-shoot IMRT, 84.7% with 3D CRT, and 69.4% with 2D techniques. D(5%) for the spinal cord changed from approximately 45 Gy with 3D plans and 46 Gy with 2D plans to approximately 28 Gy with IMRT. CONCLUSION IMRT demonstrated better target coverage and sparing of critical structures than that of 3D CRT and 2D techniques. Use of virtual critical structures resulted in removal of hot spots around the spinal cord.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer

Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...

متن کامل

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

Dosimetric verification of pre-treatment intensity modulated radiation therapy in the commissioning process

Background: Commissioning tests are recommended before implementing Intensity Modulated Radiation Therapy. This study evaluated five different plans of IMRT mocks for different modulation indices. Materials and Methods: IMRT tests were done in slab phantom for both 6MV and 15 MV photon energies using a 2D array ion chamber dosimeter. Results: The acceptance criteria were based on 3% /3mm. All t...

متن کامل

Comprehensive end-to-end test for intensity-modulated radiation therapy for nasopharyngeal carcinoma using an anthropomorphic phantom and EBT3 film

Background: In head and neck radiotherapy, immobilization devices can affect dose delivery. In this study, a comprehensive end-to-end test was developed to evaluate the accuracy of radiotherapy treatment. Materials and Methods: An Alderson Radiation Therapy (ART) anthropomorphic phantom with EBT3 film was used to mimic the actual patient treatment process. Ten patients treated for nasopharyngea...

متن کامل

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 223 1  شماره 

صفحات  -