AIMS To determine the retinal nerve fibre layer (RNFL) thickness at which visual field (VF) damage becomes detectable and associated with structural loss. METHODS In a prospective cross-sectional study, 72 healthy and 40 glaucoma subjects (one eye per subject) recruited from an academic institution had VF examinations and spectral domain optical coherence tomography (SD-OCT) optic disc cube scans (Humphrey field analyser and Cirrus HD-OCT, respectively). Comparison of global mean and sectoral RNFL thicknesses with VF threshold values showed a plateau of threshold values at high RNFL thicknesses and a sharp decrease at lower RNFL thicknesses. A 'broken stick' statistical model was fitted to global and sectoral data to estimate the RNFL thickness 'tipping point' where the VF threshold values become associated with the structural measurements. The slope for the association between structure and function was computed for data above and below the tipping point. RESULTS The mean RNFL thickness threshold for VF loss was 75.3 μm (95% CI: 68.9 to 81.8), reflecting a 17.3% RNFL thickness loss from age-matched normative value. Above the tipping point, the slope for RNFL thickness and threshold value was 0.03 dB/μm (CI: -0.02 to 0.08) and below the tipping point, it was 0.28 dB/μm (CI: 0.18 to 0.38); the difference between the slopes was statistically significant (p<0.001). A similar pattern was observed for quadrant and clock-hour analysis. CONCLUSIONS Substantial structural loss (∼17%) appears to be necessary for functional loss to be detectable using the current testing methods.
منابع مشابه
Axonal loss from acute optic neuropathy documented by scanning laser polarimetry.
BACKGROUND/AIMS Retinal nerve fibre layer analysis by scanning laser polarimetry has been shown to facilitate diagnosis of glaucoma while its role in glaucoma follow up is still unclear. A major difficulty is the slow reduction of retinal nerve fibre layer thickness in glaucomatous optic neuropathy. Eyes of patients were studied after acute retrobulbar optic nerve lesion in order to evaluate th...
متن کاملComparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma
BACKGROUND We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. MATERIAL/METHODS Study subjects had advanced primary open-angle glaucoma, pre...
متن کاملA serial study of retinal changes following optic neuritis with sample size estimates for acute neuroprotection trials.
Following an episode of optic neuritis, thinning of the retinal nerve fibre layer, which indicates axonal loss, is observed using optical coherence tomography. The longitudinal course of the retinal changes has not been well characterized. We performed a serial optical coherence tomography study in patients presenting with optic neuritis in order to define the temporal evolution of retinal nerv...
متن کاملCauses of Childhood Blindness among Students of Blinds' School in Shiraz, Iran
Background: Causes of blindness in children vary according to the region and socioeconomic development. Within a given country these causes vary with passage of time. This reflects different levels of socioeconomic development and provision of healthcare services. This cross-sectional study was undertaken to estimate the major causes of severe visual impairment in children and specially prevent...
متن کاملObjective perimetry using a four-channel multifocal VEP system: correlation with conventional perimetry and thickness of the retinal nerve fibre layer.
PURPOSE There is evidence that multifocal visual evoked potentials (VEPs) can be used as an objective tool to detect visual field loss. The aim of this study was to correlate multifocal VEP amplitudes with standard perimetry data and retinal nerve fibre layer (RNFL) thickness. METHOD Multifocal VEP recordings were performed with a four-channel electrode array using 58 stimulus fields (pattern...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 96 1 شماره
صفحات -
تاریخ انتشار 2012