Free-breathing T2* mapping using respiratory motion corrected averaging

نویسندگان

  • Peter Kellman
  • Hui Xue
  • Bruce S Spottiswoode
  • Christopher M Sandino
  • Michael S Hansen
  • Amna Abdel-Gadir
  • Thomas A Treibel
  • Stefania Rosmini
  • Christine Mancini
  • W Patricia Bandettini
  • Laura-Ann McGill
  • Peter Gatehouse
  • James C Moon
  • Dudley J Pennell
  • Andrew E Arai
چکیده

BACKGROUND Pixel-wise T2* maps based on breath-held segmented image acquisition are prone to ghost artifacts in instances of poor breath-holding or cardiac arrhythmia. Single shot imaging is inherently immune to ghost type artifacts. We propose a free-breathing method based on respiratory motion corrected single shot imaging with averaging to improve the signal to noise ratio. METHODS Images were acquired using a multi-echo gradient recalled echo sequence and T2* maps were calculated at each pixel by exponential fitting. For 40 subjects (2 cohorts), two acquisition protocols were compared: (1) a breath-held, segmented acquisition, and (2) a free-breathing, single-shot multiple repetition respiratory motion corrected average. T2* measurements in the interventricular septum and liver were compared for the 2-methods in all studies with diagnostic image quality. RESULTS In cohort 1 (N = 28) with age 51.4 ± 17.6 (m ± SD) including 1 subject with severe myocardial iron overload, there were 8 non-diagnostic breath-held studies due to poor image quality resulting from ghost artifacts caused by respiratory motion or arrhythmias. In cohort 2 (N = 12) with age 30.9 ± 7.5 (m ± SD), including 7 subjects with severe myocardial iron overload and 4 subjects with mild iron overload, a single subject was unable to breath-hold. Free-breathing motion corrected T2* maps were of diagnostic quality in all 40 subjects. T2* measurements were in excellent agreement (In cohort #1, T2*FB = 0.95 x T2*BH + 0.41, r2 = 0.93, N = 39 measurements, and in cohort #2, T2*FB = 0.98 x T2*BH + 0.05, r2 > 0.99, N = 22 measurements). CONCLUSIONS A free-breathing approach to T2* mapping is demonstrated to produce consistently good quality maps in the presence of respiratory motion and arrhythmias.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved T2-Weighted Cardiac Imaging using Retrospective Motion Correction and Optimal Image Combination

Introduction T2-weighted (T2w) cardiac MR imaging has established reputation as a sensitive technique to depict myocardial edema related to acute infarction. Together with delayed enhancement technique, T2w demonstrated valuable clinical potentials to differentiate acute damage from chronic infarction [1]. To minimize the myocardial signal loss caused by through-plane motion, T2w can be perform...

متن کامل

Free-breathing myocardial T2* mapping using GRE-EPI and automatic Non-rigid motion correction

BACKGROUND Measurement of myocardial T2* is becoming widely used in the assessment of patients at risk for cardiac iron overload. The conventional breath-hold, ECG-triggered, segmented, multi-echo gradient echo (MGRE) sequence used for myocardial T2* quantification is very sensitive to respiratory motion and may not be feasible in patients who are unable to breath-hold. We propose a free-breath...

متن کامل

Motion correction for free breathing quantitative myocardial t2 mapping: impact on reproducibility and spatial variability

Background Quantitative myocardial T2 mapping is a promising technique for in-vivo assessment of inflammation and edema [1]. Free breathing T2 mapping sequences increase the flexibility in the choice of the number of T2prep echoes times (TET2P), but should be combined with respiratory motion correction technique [2]. In this study, we sought to evaluate the performance of the Adaptive Registrat...

متن کامل

Impact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping

BACKGROUND To evaluate and quantify the impact of a novel image-based motion correction technique in myocardial T2 mapping in terms of measurement reproducibility and spatial variability. METHODS Twelve healthy adult subjects were imaged using breath-hold (BH), free breathing (FB), and free breathing with respiratory navigator gating (FB + NAV) myocardial T2 mapping sequences. Fifty patients ...

متن کامل

Free-breathing myocardial T2* mapping using GRE-EPI and MOCO for myocardial and hepatic iron overload assessment: a multi-centre study

Background T2* measurement is widely used in the assessment of patients at risk for cardiac and hepatic iron overload (1,2). The conventional breath-hold, ECG-triggered, segmented, multi-echo gradient echo sequence (BH MGRE) used for myocardial T2* quantification (3) is very sensitive to respiratory motion and may not be feasible in patients who are unable to breath-hold. To overcome this limit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015