Sensitivity of LR 115 SSNTD in a diffusion chamber

نویسندگان

  • S.Y.Y. Leung
  • D. Nikezic
  • K. N. Yu
چکیده

Solid-state nuclear track detectors (SSNTDs), such as LR 115, have been commonly used in diffusion chambers for long-term measurements of radon gas concentrations. For the LR 115 SSNTD, it has been found that the active layer removed during chemical etching is significantly affected by the presence and amount of stirring, and thus cannot be controlled easily. However, the sensitivity of the LR 115 detector inside a diffusion chamber to the radon and/or thoron gas concentration is dependent on the actual removed active layer thickness. This relationship is dependant on the geometry of the diffusion chamber and the deposition fraction of Po in the diffusion chamber, as well as the V function for the LR 115 detector (V is the ratio between the track etch velocity Vt to the bulk etch velocity Vb). This paper presents the experimentally determined relationships between the sensitivity of the LR 115 detector inside a Karlsruhe diffusion chamber and the removed active layer thickness, for both radon and thoron. A V function was adjusted to simulate the relationships. In particular, for the case of Rn, we have found f 0.5, where f is the fraction of Po which decays inside the diffusion chamber before deposition onto available inner surfaces of the chamber. In conclusion, we have found that the sensitivities critically depend on the actual removed active layer thickness, so this should be monitored and used in determining the sensitivities. 2007 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Derivation of V function for LR 115 SSNTD from its sensitivity to 220Rn in a diffusion chamber.

The sensitivity of the LR 115 detector inside a diffusion chamber to (220)Rn gas concentration is dependent on the removed active layer thickness during chemical etching. This dependence is related to the V function for the LR 115 detector (where V is the ratio between the track etch velocity V(t) and the bulk etch velocity V(b)) and the geometry of the diffusion chamber. The present paper pres...

متن کامل

Derivation of V function for LR 115 SSNTD from its partial sensitivity to 222Rn and its short-lived progeny.

Solid-state nuclear track detectors (SSNTDs) have been widely applied for measurements of environmental concentrations of 222Rn and its progeny. The V function for an SSNTD is important for understanding the track development in the SSNTD as well as for real life applications. The partial sensitivity rhoi of the LR 115 detector applied in the bare mode to 222Rn and its short-lived progeny is re...

متن کامل

A study of the polyethylene membrane used in diffusion chambers for radon gas concentration measurements

Solid-state nuclear track detectors (SSNTDs) in diffusion chambers have been routinely used for long-term measurements of radon gas concentrations. In usual practice, a filter is added across the top of the diffusion chamber to stop the progeny from entering. Thoron can also be deterred from entering the diffusion chamber by using a polyethylene (PE) membrane. However, the thickness of the PE m...

متن کامل

Fast and non-destructive determination of active-layer thickness of LR 115 SSNTD using a color commercial document scanner

Measurements using the LR 115 solid-state nuclear track detector (SSNTD) depend critically on the removed thickness of the active layer during etching, which cannot be controlled by the etching period alone. For example, the bulk etch rate depends significantly on the strength of stirring during etching. We propose here a fast, inexpensive and nondestructive method based on a color commercial d...

متن کامل

Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD

Background: Separate radon and thoron measurements in soil are very important in assessment of internal exposure due to inhalation of such radioactive gases. Materials and Methods: In this study, a low cost, small size, passive diffusion chamber has been developed for simple measurement of Radon-222 and Radon-220(Thoron) gases separately in soil. The diffusion chamber consists of two films and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007