On-chip two-phase cooling of datacenters: Cooling system and energy recovery evaluation

نویسندگان

  • Jackson Braz Marcinichen
  • Jonathan Albert Olivier
  • John Richard Thome
چکیده

Cooling of datacenters is estimated to have an annual electricity cost of 1.4 billion dollars in the United States and 3.6 billion dollars worldwide. Currently, refrigerated air is the most widely used means of cooling datacenter’s servers, which typically represents 40e45% of the total energy consumed in a datacenter. Based on the above issues, thermal designers of datacenters and server manufacturers now seem to agree that there is an immediate need to improve the server cooling process. The goal of the present study is to propose and simulate the performance of a novel hybrid two-phase cooling cycle with micro-evaporator elements (multi-microchannel evaporators) for direct cooling of the chips and auxiliary electronics on blade server boards (savings in energy consumption of over 60% are expected). Different working fluids were considered, namely water, HFC134a and a new, more environmentally friendly, refrigerant HFO1234ze. The results so far demonstrated that the pumping power consumption is on the order of 5 times higher for the water-cooled cycle. Additionally, a case study considering the hybrid cooling cycle applied on a datacenter and exploring the application of energy recovered in the condenser on a feedwater heater of a coal power plant was also investigated (modern datacenters require the dissipation of 5e15 MW of heat). Aspects such as minimization of energy consumption and CO2 footprint and maximization of energy recovery (exergetic efficiency) and power plant efficiency are investigated. 2011 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy efficiency in a building complex through seasonal storage of thermal energy in a confined aquifer

Confined aquifers are formations surrounded by impermeable layers called cap rocks and bed rocks. These aquifers are suitable for the seasonal storage of thermal energy. A confined aquifer was designed to meet the cooling and heating energy needs of a residential building complex located in Tehran, Iran. The annual cooling and heating energy needs of the buildings were estimated to be 8.7...

متن کامل

Techno-Economic Assessment of Different Inlet Air Cooling Systems in Warm Dry & Wet Climate Stations

Performance of a gas turbine mainly depends on the inlet air temperature. The power output of a gas turbine depends on the flow of mass through it. This is precisely the reason why on hot days, when air is less dense, power output falls. The objective here is to assess the advanced systems applied in reducing the gas turbine intake air temperature and examine the merits from integration of the ...

متن کامل

Effect of Velocity and Direction of Airflow on Thermal Comfort and Energy Consumption: Case of New Exclusive Cooling Systems

The application of personalized ventilation systems, particularly in the buildings, is one of the new topics that today presented to it, because of their proper performance in reducing energy consumption and creating better thermal comfort conditions. In the current study, the energy consumption of a personalized cooling system installed in a room, considering the constraint of thermal comfort,...

متن کامل

Application of Phase Change Material (PCM) for Cooling Load Reduction in Lightweight and Heavyweight Buildings: Case Study of a High Cooling Load Region of Iran

The application of phase change material (PCM) for energy conservation purposes in the residential buildings was investigated in the present study. Two types of building in terms of materials as the lightweight building (LWB) and heavyweight building (HWB) located in a high cooling load demanding region of Iran were considered for the study. Different types of PCM from organic and inorganic cat...

متن کامل

The Study of Thermostat Impact on Energy Consumption in a Residential Building by Using TRNSYS

The present study investigates the effectiveness of thermostat control strategy in cooling energy consumption in residential buildings. To evaluate the energy consumption, two scenarios including a residential zone with and without the thermostat control system are assumed. The TRNSYS software provides an efficient numerical tool to model and evaluate a cooling system. Furthermore, since solar-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011