An improved trap design for decoupling multinuclear RF coils.

نویسندگان

  • Martin Meyerspeer
  • Eulalia Serés Roig
  • Rolf Gruetter
  • Arthur W Magill
چکیده

PURPOSE Multinuclear magnetic resonance spectroscopy and imaging require a radiofrequency probe capable of transmitting and receiving at the proton and non-proton frequencies. To minimize coupling between probe elements tuned to different frequencies, LC (inductor-capacitor) traps blocking current at the (1)H frequency can be inserted in non-proton elements. This work compares LC traps with LCC traps, a modified design incorporating an additional capacitor, enabling control of the trap reactance at the low frequency while maintaining (1)H blocking. METHODS Losses introduced by both types of trap were analysed using circuit models. Radiofrequency coils incorporating a series of LC and LCC traps were then built and evaluated at the bench. LCC trap performance was then confirmed using (1)H and (13)C measurements in a 7T human scanner. RESULTS LC and LCC traps both effectively block interaction between non-proton and proton coils at the proton frequency. LCC traps were found to introduce a sensitivity reduction of 5±2%, which was less than half of that caused by LC traps. CONCLUSION Sensitivity of non-proton coils is critical. The improved trap design, incorporating one extra capacitor, significantly reduces losses introduced by the trap in the non-proton coil.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A monopole/loop dual-tuned RF coil for ultrahigh field MRI.

Proton and heteronuclear MRI/MRS using dual-tuned (DT) coils could provide both anatomical and metabolic images without repositioning the subject. However, it is technologically challenging to attain sufficiently electromagnetic (EM) decoupling between the heteronuclear channel and proton channel, and keep the imaging areas and profiles of two nuclear channels highly matched. In this study, a h...

متن کامل

Trap Design Performance for RF Coils for Dual-frequency MRI & MRS

Introduction The growing availability of high-field whole body scanners has generated increasing interest in non-proton in vivo spectroscopy, and with it, multinuclear RF coil design. In most non-proton applications, simultaneous or sequential operation at the proton frequency is required as well; proton decoupling, scout imaging, and polarization transfer methods are cases where transmission/r...

متن کامل

A Composite Decoupling Method for RF Transceiver Array Coils in MRI

Introduction Although widely embraced in clinical applications, array coils [1] still pose tremendous design challenges due to coupling between coil elements [2]. Several strategies have been proposed for eliminating mutual inductance, such as overlapping [1, 3], orthogonal positioning [3], use of low impedance preamplifiers [1], digital postprocessing [4], capacitive/inductive networks [5] and...

متن کامل

Novel Concepts for RF Surface Coils with Integrated Receivers

Magnetic Resonance Imaging (MRI) is a powerful non-invasive reconstruction tool used primarily in the medical community to produce high quality images of the human anatomy. Surface coils are Radio Frequency (RF) systems typically deployed for receiving the MR signals. Multiple surface coils, or an array of coils, are employed to obtain a localized improvement in the signal-to-noise ratio withou...

متن کامل

Novel optically tunable capacitor for RF safe tuning and decoupling of intravascular MR coils

S. Weiss, T. Uelzen, G. Pantel, J. Mueller Philips Research Laboratories, Hamburg, Germany, Department of Micro Systems Technology, Hamburg University of Technology, Hamburg, Germany, MRI Devices Daum GmbH, Schwerin, Germany Objective: The motivation for the application of intravascular imaging coils is to gain high SNR images from a local area. To maximize SNR, proper tuning and matching of su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 72 2  شماره 

صفحات  -

تاریخ انتشار 2014