Fluorescence Imaging Analysis of Transient Trapping–microchip Micellar Electrokinetic Chromatography

نویسنده

  • K. Sueyoshi
چکیده

This paper reports an fluorescence imaging analysis to verify the proposed mechanisms in transient trapping– microchip micellar electrokinetic chromatography (tr-trapping–MCMEKC). Fluorescence imaging revealed that a process of tr-trapping consisted of four migration stages with different apparent diffusion constants. In the first trapping stage, the diffusion of a focused sample band was suppressed on a boundary between the sample and partially injected micellar zones, while the sample bands slowly diffused in the micellar zone under the conventional sweeping condition. In the second releasing stage, it was clarified that the difference in the releasing time provided a highly effective separation compared to the conventional MCMEKC in spite of the shorter length of the micellar solution zone. In the third and fourth stages, the concentrated and separated samples migrated according to the principle of MEKC and zone electrophoresis, respectively. As a result, it was confirmed that the highly effective preconcentration and separation obtained in tr-trapping–MCMEKC was well explained by our proposed mechanism.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-Dimensional Microchip Electrophoresis of Proteins

The popularity of micro-Total Analysis Systems (μ-TAS) is exponentially increasing, especially in the fields of medical and biological analyses. The work presented here includes 2-D separation of proteins in PMMA-based microchips. Sodium Dodecyl Sulfate Capillary Gel Electrophoresis (SDS-CGE) and Micellar Electrokinetic Chromatography (MEKC) were used as the separation scheme for the first and ...

متن کامل

Modeling The Capacity Factor of Analytes in Micellar Electrokinetic Chromatography Using Computational Descriptors

       A multiple linear regression model is proposed to calculate capacity factor of  analytes using structural features computed using HyperChem software. The  chemical descriptors of analytes were computed using HyperChem software and  regressed against the experimental capacity factors of analytes collected from the  literature. The absolute average percentage deviation (AARD) and individua...

متن کامل

Poly(dimethylsiloxane) microchip for precolumn reaction and micellar electrokinetic chromatography of biogenic amines.

We have demonstrated that precolumn derivatization and capillary electrophoresis separation on a poly(dimethylsiloxane) (PDMS) microchip can be realized as efficient as those on glass microchips. In an optimized condition of micellar electrokinetic chromatography (MEKC), using 25 mM sodium borate buffer (pH 10.0) with 25 mM sodium dodecyl sulfate (SDS) and 5% v/v methanol, the electroosmotic fl...