Detection of endotoxin on sterile catheters used for cardiac catheterization.

نویسندگان

  • R B Kundsin
  • C W Walter
چکیده

Pyrogen reactions during cardiac catheterization are an alarming complication that frightens patients and baffles many physicans. This report describes a simple, reproducible, precise technique for the measurement of endotoxin-like activity on the inner and outer surfaces of catheters intended for intravascular insertion. This technique is useful in documenting the cause of patient reactions. Quality control procedures should be instituted following the manufacture of angiographic catheters so that pyrogen-free products are availabe for patient use. Catheters processed in a hospital are easily contaminated with fever-producing lipopolysaccharides from tap water or from bacterial growth in residual moisture. Sterilization by steam or ethylene oxide does not destroy these lipopolysaccharides. Consequently, reprocessing reusable catheters must include concern for removing lipopolysaccharides as well as sterilization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complications of Peripheral Intravenous Catheters During 72 Hours After Insertion

Introduction: Peripheral Intravenous catheterization is the most commonly used invasive treatment method in patients admitted to the hospitals, but it has some complications. The indwell time of catheter is one of the factors associated with the occurrence of complications, especially phlebitis. In spite of the instructions for replacing the catheters after 72 hours, sometimes the complications...

متن کامل

Cold Sterilization of Cardiac Catheterization Equipment with Ethylene Oxide Gas.

OCCASIONAL infections in sites of venous cutdowns and an episode of fever in a patient following cardiac catheterization caused us to review the procedures used in this laboratory for preparation of catheterization equipment. Materials not susceptible to damage by wet heat (surgical instruments, syringes and needles, drapes) are sterilized in a steam autoclave. Polyethylene catheters, cuvette o...

متن کامل

The successful withdrawal of a migrated central venous catheter

Background: Central venous catheters (CVCs) have been used widely in clinics. These catheters are also recommended for children and infants receiving chemotherapy and total parenteral nutrition (TPN) and etc. In this paper, we present migrated fractured control line of the heart of a girl. Case Presentation: A 2.5 year old girl with migrated of the fractured central line into the heart. In the ...

متن کامل

The need for maximal sterile barrier precaution in routine interventional coronary procedures; microbiology analysis

BACKGROUND Maximal sterile barrier precautions (MSBP) including head coverings and face masks are advocated for use in invasive procedures, including coronary interventions. The rationale for MSBP assumes it is an obligatory measure for infection prevention. However, in many coronary catheterization laboratories, head coverings/face masks are not used in daily practice. This study prospectively...

متن کامل

عوامل تاثیر گذار بر شدت کمردرد بیماران بعد از آنژیوگرافی قلبی

  Background and Aim: Cardiac catheterization is a widely used cardiac investigation procedure in Iran. However, back pain is frequently reported following cardiac catheterization due to prolonged bed rest after the procedure. There is no research about factors that affect back pain. This study was designed to explore these factors in patients admitted to Taleghani hospital for cardiac catheter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 1980