Diagnostic reference levels from the ACR CT Accreditation Program.

نویسندگان

  • Cynthia McCollough
  • Theresa Branham
  • Vince Herlihy
  • Mythreyi Bhargavan
  • Lavonne Robbins
  • Krista Bush
  • Michael McNitt-Gray
  • J Thomas Payne
  • Tom Ruckdeschel
  • Doug Pfeiffer
  • Dianna Cody
  • Robert Zeman
چکیده

PURPOSE The aim of this study was to assess the distribution of CT dose index (CTDI) values reported by sites undergoing ACR CT accreditation between 2002 and 2004. METHODS Weighted CTDI (CTDI(w)) values were measured and reported by sites applying for ACR CT accreditation, and the percentage of scanners with values above the 2002 ACR diagnostic reference levels (DRLs) was determined. Acquisition parameters for a site's adult head, adult abdominal, and pediatric abdominal examinations were used to calculate volume CTDI (CTDI(vol)), and the average and standard deviation were calculated by year. Histogram analysis was performed to determine 75th and 90th percentiles of CTDI(vol). RESULTS Between September 2002 and December 2004, 829 scanners underwent the accreditation process. Volume CTDI values (average ± SD) for 2002, 2003, 2004, and 2002 to 2004, respectively, were 66.7 ± 23.5, 58.5 ± 17.5, 55.8 ± 15.7, and 59.1 ± 18.6 mGy for adult head examinations; 18.7 ± 8.0, 19.2 ± 8.6, 17.0 ± 7.6, and 18.4 ± 8.3 for adult abdominal examinations; and 17.2 ± 9.7, 15.9 ± 8.6, 14.0 ± 7.0, and 15.5 ± 8.4 for pediatric abdominal examinations. For 2004 data, 23.8%, 2.3%, and 6.9% of sites reported doses above the 2002 CTDI(w) reference levels, compared with 49.6%, 4.7%, and 15% for 2002 data for adult head, adult abdominal, and pediatric abdominal examinations, respectively. Seventy-fifth percentiles of CTDI(vol) were 76.8 mGy (adult head, 2002 only), 22.2 mGy (adult abdominal), and 20.0 mGy (pediatric abdominal). CONCLUSIONS From 2002 to 2004, average CTDI(vol) values decreased by 10.9, 1.7, and 3.2 mGy for adult head, adult abdominal, and pediatric abdominal examinations. Effective January 1, 2008, the ACR program implemented United States-specific diagnostic reference levels of 75, 25, and 20 mGy, respectively, for the CTDI(vol) of routine adult head, adult abdominal, and pediatric abdominal CT scans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The phantom portion of the American College of Radiology (ACR) computed tomography (CT) accreditation program: practical tips, artifact examples, and pitfalls to avoid.

The ACR CT accreditation program, begun in 2002, requires the submission of approximately 20 images, several completed data sheets and printouts of three Excel worksheets. The procedure manual is very detailed, yet participants unfamiliar with the program or having minimal CT experience have needed to redo aspects of their submission, or in some cases do not receive accreditation, due to mistak...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Using the ACR CT accreditation phantom for routine image quality assurance on both CT and CBCT imaging systems in a radiotherapy environment

Image-guided radiation therapy using cone-beam computed tomography (CBCT) is becoming routine practice in modern radiation therapy. The purpose of this work was to develop an imaging QA program for CT and CBCT units in our department, based on the American College of Radiology (ACR) CT accreditation phantom. The phantom has four testing modules, permitting one to test CT number accuracy, slice ...

متن کامل

Diagnostic Reference Level of Computed Tomography Examinations and Need for Dose Optimization in Ondo State, Nigeria

Introduction: The present study was conducted to obtain State diagnostic reference levels (DRLs) of five routine computed tomography (CT) examinations from two CT centers in Ondo State and to identify factors responsible for dose variation and escalation in these CT centers. Material and Methods: Acquisition parameters and CT dose indices wer...

متن کامل

Establishment of Diagnostic Reference Levels and Estimation of Effective Dose from Computed Tomography Head Scans at a Tertiary Hospital in South Africa

Introduction: Head scans are the most frequently performed computed tomography (CT) examinations worldwide. However, there is growing concern over the probability of increased cancer risks among the exposed populations. Diagnostic reference levels (DRLs) identify radiation dose that is not commensurate with clinical objectives. The aim of this study was to establish DR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Radiology : JACR

دوره 8 11  شماره 

صفحات  -

تاریخ انتشار 2011