Positron emission tomography alone, positron emission tomography-computed tomography and computed tomography in diagnosing recurrent cervical carcinoma: a systematic review and meta-analysis

نویسندگان

  • Yi Xiao
  • Jia Wei
  • Yicheng Zhang
  • Weining Xiong
چکیده

INTRODUCTION The aim of the study was to assess systematically the accuracies of positron emission tomography (PET), PET/computed tomography (CT), and CT in diagnosing recurrent cervical cancer. MATERIAL AND METHODS We searched for articles published from January 1980 to June 2013 using the following inclusion criteria: articles were reported in English; the use of PET, interpreted with or without the use of CT; use of CT to detect recurrent cervical cancer; and histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months. We extracted data to calculate sensitivity, specificity, summary receiver operating characteristic curves, and the area under the receiver operating characteristic curve (AUC) as well as test for heterogeneity. RESULTS In 23 included studies, PET had the highest pooled specificity at 92% (95% CI: 90-94), whereas PET/CT had the highest pooled sensitivity at 94% (95% CI: 90-97). The area under the curve (AUC) of PET alone, PET/CT, and CT were 0.9594, 0.9508, and 0.9363, respectively. Results of the pairwise comparison between each modality show that the specificity of PET was higher than that of PET/CT (p < 0.05). The difference in the pooled sensitivities and AUC of PET alone and PET/CT showed no statistical significance. No evidence of publication bias was found. However, evidence of heterogeneity was observed. CONCLUSIONS The PET/CT may be a useful supplement to current surveillance techniques, particularly for patients with negative CT imaging. However, in terms of diagnostic accuracy, interpreted CT images may have limited additional value to PET in detecting recurrent cervical cancer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sectional anatomy quiz

This mage based series comprises of a quiz pertaining to the identification of salient anatomical structures expected to be seen at a given level on the computed tomography (CT) followed by examples of multiple representative pathologies that can be seen at the same level in a routine clinical setting. It is expected that this will improve confidence of nuclear physicians in interpretation of t...

متن کامل

Neuroimaging in Iran: A Review

ABSTRACTNeuroimaging allows noninvasive evaluation of the anatomy, physiology, and function of the brain. It is widely used for diagnosis, treatment planning, and treatment evaluation of neurological disorders as well as understanding functions of the brain in health and disease. Neuroimaging modalities include X-ray computed tomography (CT), magnetic resonance imaging (MRI), single photon emis...

متن کامل

Detection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging

Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging  yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...

متن کامل

A Comparative Study of the Construction of Positron Emission Tomography/Computed Tomography Facilities in Three South African Hospitals

Introduction: Development of higher energy modalities such as positron emission tomography/computed tomography (PET/CT), has led to more complex shielding problems. This is due to several factors, such as the radiopharmaceutical relatively high-administered activity, high patient throughput, and high energies of 511 kilo-electron volt (keV) positron annihilation photon...

متن کامل

Performance of Positron Emission Tomography and Positron Emission Tomography/Computed Tomography Using Fluorine-18-Fluorodeoxyglucose for the Diagnosis, Staging, and Recurrence Assessment of Bone Sarcoma: A Systematic Review and Meta-Analysis: Erratum

I n the article ‘‘Performance of Positron Emission Tomography and Positron Emission Tomography/Computed Tomography Using Fluorine-18-Fluorodeoxyglucose for the Diagnosis, Staging, and Recurrence Assessment of Bone Sarcoma: A Systematic Review and Meta-Analysis’’, which appeared in Volume 94, Issue 36 of Medicine, Dr. Fengxia Liu’s name was omitted from the byline, Dr. Zhu’s degree was incorrect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2014