Preventing ascorbate interference in ion-chromatographic determinations of urinary oxalate: four methods compared.

نویسندگان

  • M Petrarulo
  • M Marangella
  • O Bianco
  • A Marchesini
  • F Linari
چکیده

In an attempt to decrease ascorbate interference on the ion-chromatographic determination of urinary oxalate, we compared the effectiveness of four different methods for ascorbate elimination by analyzing a representative urine pool supplemented with successive ascorbate additions. Two of the methods--treatment with ferric ions or boric acid--have been described elsewhere; treatments with nitrites or ascorbate oxidase (EC 1.10.3.3) are investigated here as possible alternatives. Consideration of the main features, advantages, and drawbacks of the four procedures leads us to conclude that boric acid dilution is a good routine method and that pre-incubation with ascorbate oxidase reliably prevents ascorbate interference in assays of urinary oxalate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modified enzyme-based colorimetric assay of urinary and plasma oxalate with improved sensitivity and no ascorbate interference: reference values and sample handling procedures.

The measurement of oxalate in urine and plasma continues to be difficult, particularly in the presence of ascorbate. We have modified and validated a colorimetric assay involving the use of oxalate oxidase (EC 1.2.3.4). Modification of an HPLC spectrophotometric detector improved sensitivity (to as much as 1000-fold that of conventional spectrophotometers) and allowed measurement of oxalate con...

متن کامل

Measurement of urinary oxalate: an enzymatic and an ion chromatographic method compared.

An ion chromatographic and an enzymatic method for determination of oxalic acid in urine were compared on the basis of reliability and practicability. Both methods displayed a within-run imprecision of under 5% and a total imprecision of under 10%. The mean recovery of 0.2 mmol/l sodium oxalate lay close to 100% for both methods. After 80 parallel determinations, both methods produced statistic...

متن کامل

Urinary oxalate determination by use of immobilized oxalate oxidase in a continuous-flow system.

In this procedure, oxalate oxidase (EC 1.2.3.4) immobilized in a continuous-flow system is used to determine oxalate in urine. The hydrogen peroxide formed from oxalate is detected by use of a color reaction with peroxidase (EC 1.11.1.7), 3-methyl-2-benzothiazoline hydrazine, and N,N-dimethylalanine. However, urine contains an oxalate oxidase inhibitor, which cannot be removed by heating, ion-e...

متن کامل

Five treatment procedures evaluated for the elimination of ascorbate interference in the enzymatic determination of urinary oxalate.

We evaluated the efficacies of five treatment procedures for eliminating ascorbate interference in the enzymatic determination of urinary oxalate. Aliquots of urine samples, containing different amounts of added ascorbate and oxalate, were individually subjected to ferric chloride, sodium nitrite, sodium periodate, charcoal, or ascorbate oxidase treatment to eliminate ascorbate interference. Ox...

متن کامل

An enzymatic method for oxalate automated with the Cobas Fara centrifugal analyzer.

Measurement of oxalate in urine has been automated for use with the Cobas Fara centrifugal analyzer. No sample pretreatment other than (a critical) pH adjustment is required. Between-run CVs were less than 4%. Results were linearly related to oxalate concentration to 1000 mumol/L. Ascorbic acid ingestion, up to 5 g of ascorbate daily, caused no demonstrable interference with the assay. This pra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 36 9  شماره 

صفحات  -

تاریخ انتشار 1990