Reliability of six physical performance tests in older people with dementia.

نویسندگان

  • Christiaan G Blankevoort
  • Marieke J G van Heuvelen
  • Erik J A Scherder
چکیده

BACKGROUND Physical performance tests are important for assessing the effect of physical activity interventions in older people with dementia, but their psychometric properties have not been systematically established within this specific population. OBJECTIVE The purpose of this study was to determine the relative and absolute test-retest reliability of the 6-m walk test, the figure-of-Eight Walk Test (F8W), the Timed "Up & Go" Test (TUG), the Frailty and Injuries: Cooperative Studies of Intervention Techniques-4 (FICSIT-4) Balance Test, the Chair Rise Test (CRT), and the Jamar dynamometer. These tests are used to assess gait speed, dynamic balance, functional mobility, static balance, lower-limb strength, and grip strength, respectively. DESIGN This investigation was a prospective, nonexperimental study. METHODS Older people with dementia (n=58, age range=70-92 years) performed each test at baseline and again after 1 week. Intraclass correlation coefficients (ICC), standard error of measurement (SEM), minimal detectable change (MDC), and log-transferred limits of agreement of Bland-Altman plots were calculated. RESULTS The relative reliability of the F8W, TUG, and Jamar dynamometer was excellent (ICC=.90-.95) and good for the 6-m walk test, FICSIT-4, and CRT (ICC=.79-.86). The SEMs and MDCs were large for all tests. The absolute reliability of the TUG and CRT was significantly influenced by the level of cognitive functioning (as assessed with the Mini-Mental State Examination [MMSE]). LIMITATIONS The specific etiology of dementia was not obtained. CONCLUSIONS The physical performance tests evaluated are useful for detecting differences in performance between older people with mild to moderate dementia and, therefore, are suitable for cross-sectional or controlled intervention studies. They appear less suitable to monitor clinically relevant intra-individual performance changes. Future studies should focus on the development of more sensitive tests and the identification of criteria for clinically relevant changes in this rapidly growing population.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

“Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia”

BACKGROUND The purpose of the study was to establish the test-retest reliability of the Norwegian version of the Short Physical Performance Battery (SPPB). METHODS This was a cross- sectional reliability study. A convenience sample of 61 older adults with a mean age of 88.4(8.1) was tested by two different physiotherapists at two time points. The mean time interval between tests was 2.5 days....

متن کامل

The Groningen Meander Walking Test: a dynamic walking test for older adults with dementia.

BACKGROUND Current dynamic walking tests, used in studies with older adults with dementia, rely strongly on healthy cognitive and physical function. Therefore, the Groningen Meander Walking Test (GMWT) was developed specifically for people with dementia. The aim of the GMWT is to measure dynamic walking ability by walking over a meandering curved line, with an emphasis on walking speed and step...

متن کامل

Assessing the validity and reliability of the Pool Activity Level (PAL) Checklist for use with older people with dementia.

Activity is key to maintaining physical and mental health and well-being. However, as dementia affects the ability to engage in activity, care-givers can find it difficult to provide appropriate activities. The Pool Activity Level (PAL) Checklist guides the selection of appropriate, personally meaningful activities. The aim of this study was to assess the reliability and validity of the PAL Che...

متن کامل

Reliability of Identification of Seniors at Risk Screening Tool in Predicting Functional and Mental Decline in Discharged Elderly Patients

Introduction: Emergency wards today are facing with an increasing numbers of older patients. Therefore, it seems important and essential to develop a short screening tool with an acceptable predictive power to identify the seniors being discharged from hospital and mean while are at risk of a decline in physical and mental performance, and thus, facing re-admission emergency wards in hospitals....

متن کامل

پایایی و روایی آزمون ترسیم ساعت در سالمندان

Objectives: Early diagnosis of cognitive disorders in order to initiate new efficient treatments in time is an important task which cannot be fulfilled without proper cognitive screening tools. The Clock Drawing Test (CDT) is a simple inexpensive cognitive screening tool which can be used in primary care settings delivering health services to older people. The aim of this study was to assess va...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical therapy

دوره 93 1  شماره 

صفحات  -

تاریخ انتشار 2013