Outcomes of long tapered hydroxyapatite-coated stems in revision total hip arthroplasty.
نویسندگان
چکیده
The purpose of this study was to evaluate the outcome of femoral component revisions using a long tapered HA coated femoral revision stem. Between 2001 and 2008, 55 femoral component revisions were performed using this stem. Forty-one patients were available for follow up evaluation at average of 59 months. The clinical results were evaluated using the HHS and serial radiographs were evaluated for loosening. The mean HHS was 71 (range 22-100). Three hips required revision of KAR stem (1 aseptic loosening, 1 infection, 1 limb length discrepancy). Only one prosthesis demonstrated radiographic evidence of subsidence. Our study suggests that long tapered HA coated revision femoral components can provide stable fixation and in-growth in cases where there is good proximal femoral bone stock and favorable canal geometry.
منابع مشابه
Effects of hydroxyapatite coating on survival of an uncemented femoral stem
BACKGROUND AND PURPOSE Hydroxyapatite (HA) is widely used as a coating for uncemented total hip arthroplasty components. This has been suggested to improve implant ingrowth and long-term stability. However, the evidence behind the use of HA coating on femoral stems is ambiguous. We investigated survival of an uncemented, tapered titanium femoral stem that was available either with or without HA...
متن کاملStubby stems: good things come in small packages.
Standard-length porous-coated tapered femoral stems perform exceedingly well in primary total hip arthroplasty (THA) at long-term follow-up. Nevertheless, there are multiple reasons to strongly consider the relatively new concept of short tapered stems. First, there is already a wide variation in the lengths of "standard" components and the ideal length is unknown. The goal of tapered stems is ...
متن کاملThe Effect of Hydroxyapatite Coating on Long-term Results of Total Hip Arthroplasty with Hydroxyapatite-coated Anatomic Femoral Stem
PURPOSE To evaluate the clinical and radiological results, as well as the survival rate, associated with total hip arthroplasty using a hydroxyapatite (HA)-coated anatomical femoral stem at a follow-up of ≥12 years. MATERIALS AND METHODS From April 1992 to May 1997, 86 patients (102 hips) underwent total hip arthroplasty with a HA-coated ABG I (Anatomical Benoist Giraud; Howmedica) hip prosth...
متن کاملDistal fixation of proximally coated tapered stems may predispose to a failure of osteointegration.
Despite excellent long-term results of proximally coated tapered wedge femoral stems in noncemented total hip arthroplasty, we have consistently observed a minority fail to achieve osteointegration. We retrospectively reviewed 320 consecutive total hip arthroplasties performed by a single surgeon using a single stem over a 4-year period. Clinical and radiographic parameters were analyzed for ri...
متن کاملResults of a hydroxyapatite-coated femoral stem (Corail) in Chinese: a minimum 10-year follow-up
BACKGROUND Due to the adverse effects of cemented hip arthroplasty, uncemented stems with hydroxyapatite (HA) coating reduces these risks and enhanced integration. The concept of an extensive HA coating for the fixation of a tapered femoral stem (Corail®) was introduced, which can achieve durable biological fixation and preserve normal periprosthetic bone activity. Here we describe the clinical...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 29 4 شماره
صفحات -
تاریخ انتشار 2014