Left Atrial Volumes and Function by Three-Dimensional Echocardiography: Reference Values, Accuracy, Reproducibility, and Comparison With Two-Dimensional Echocardiographic Measurements.
نویسندگان
چکیده
BACKGROUND Our study sought to (1) identify reference values for left atrial (LA) volumes and phasic function indices by 3-dimensional echocardiography (3DE) and compare them with those measured by 2-dimensional echocardiography (2DE) and (2) analyze their relationship with age, sex, body size, and left ventricular function. Accuracy and reproducibility of 3DE and 2DE have been also tested to evaluate the robustness of our data. METHODS AND RESULTS We obtained maximal, minimal, and preA LA volumes by 3DE and 2DE in 276 healthy volunteers (18-79 years; 57% women). Limits of normality for LA volumes and total LA emptying fraction were larger with 3DE than with 2DE (maximal LA volume: 43 versus 35 mL/m(2); preA LA volume: 31 versus 25 mL/m(2); minimal LA volume: 18 versus 14 mL/m(2); 53 versus 48%, respectively; P<0.001). 3DE LA volumes indexed by body surface area were similar in men and women and increased with age. On multivariable analysis, age, weight, and left ventricular systolic and diastolic function indices resulted as correlates of LA 3DE indices. LA volumes were tightly correlated with cardiac magnetic resonance measurements, yet more underestimated by 2DE versus 3DE (bias±SD: -17±16 versus -7±15 mL, respectively). Among all LA parameters, maximal LA volume and total emptying fraction were the most reproducible, including at test-retest and at expert versus trainee comparisons. CONCLUSIONS This study provides reference values for LA 3DE volumes and function from a relatively large cohort of healthy subjects with a wide age range. Our data may help clinicians to identify LA remodeling and dysfunction.
منابع مشابه
Automated left heart chamber volumetric assessment using three-dimensional echocardiography in Chinese adolescents
BACKGROUND Several studies have reported the accuracy and reproducibility of HeartModel for automated determination of three-dimensional echocardiography (3DE)-derived left heart volumes and left ventricular (LV) ejection fraction (LVEF) in adult patients. However, it remains unclear whether this automated adaptive analytics algorithm, derived from a 'training' population, can encompass adequat...
متن کاملReference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs
Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...
متن کاملEchocardiographic assessment of right ventricular volumes after surgical repair of tetralogy of Fallot: clinical validation of a new echocardiographic method.
BACKGROUND Assessment of right ventricular (RV) volumes and function is important in patients after tetralogy of Fallot (TOF) repair. Currently, cardiac magnetic resonance imaging (MRI) is considered the clinical reference method for RV volume and function measurements. Three-dimensional (3D) knowledge-based reconstruction derived from two-dimensional echocardiographic imaging with magnetic tra...
متن کاملQuantification of left ventricular volumes using three-dimensional echocardiographic speckle tracking: comparison with MRI.
AIMS Although the utility of two-dimensional (2D) speckle tracking echocardiography (STE) to quantify left ventricular (LV) volume has been demonstrated, this methodology is limited by foreshortened views, geometric modelling, and the assumption that speckles can be tracked from frame to frame, despite their out of plane motion. To circumvent these limitations, a three-dimensional (3D) speckle ...
متن کاملEffect of position on echocardiographic diagnosis of mitral valve prolapse
Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular imaging
دوره 9 7 شماره
صفحات -
تاریخ انتشار 2016