Validation of quantitative bound- and pore-water imaging in cortical bone.

نویسندگان

  • Mary Kate Manhard
  • R Adam Horch
  • Kevin D Harkins
  • Daniel F Gochberg
  • Jeffry S Nyman
  • Mark D Does
چکیده

PURPOSE To implement and validate a previously proposed ultra-short echo time method for measuring collagen-bound- and pore-water concentrations in bone based on their T2 differences. METHODS Clinically compatible ultra-short echo time image sequences for quantitative T2 -based bound and pore-water imaging in bone were implemented and validated on a 3T human scanner and a 4.7T small bore system. Bound- and pore-water images were generating using T2 -selective adiabatic pulses. In both cases, the magnetization preparation was integrated into a three-dimensional ultra-short echo time acquisition, with 16 radial spokes acquired per preparation. Images were acquired from human cadaveric femoral mid-shafts from which isolated bone samples were subsequently extracted for nonimaging analysis using T2 spectroscopic measurements. RESULTS A strong correlation was found between imaging-derived concentrations of bound and pore water and those determined from the isolated bone samples. CONCLUSIONS These studies demonstrate the translation of the previously developed approaches for distinguishing bound and pore water from human cortical bone using practical human MRI constraints of gradient performance and radiofrequency power deposition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

30-Second bound and pore water concentration mapping of cortical bone using 2D UTE with optimized half-pulses.

PURPOSE MRI of cortical bone has the potential to offer new information about fracture risk. Current methods are typically performed with 3D acquisitions, which suffer from long scan times and are generally limited to extremities. This work proposes using 2D UTE with half pulses for quantitatively mapping bound and pore water in cortical bone. METHODS Half-pulse 2D UTE methods were implemente...

متن کامل

MRI Measures of Cortical Bone Water Concentration: Dependence on Age and Pore Volume Fraction

Introduction: Age-related increase in cortical bone porosity is a major cause of the impaired strength of osteoporotic cortical bone. The majority of these pores, however, are below the resolution limit achievable in vivo. Water H NMR signal in bone at 3T results from two compartments: long T2 (T2 ≥ 1 ms), corresponding to free water in pores (‘pore water’); and short T2 (T2 ~ 300-400 μs), corr...

متن کامل

Quantifying Proton Density in Cortical Bone In-Vivo by 3D Ultra-short Echo-time Imaging

Synopsis The impaired strength of osteoporotic cortical bone is largely a consequence of increased porosity, which manifests in increased bone water fraction. Hence, knowledge of bone water (BW) content would provide an indirect measure of pore volume fraction. Surface interactions in the tight spaces of the lacuno-canalicular system shorten the lifetime of the BW proton signal to less than 1ms...

متن کامل

Towards assessing cortical bone porosity using low-frequency quantitative acoustics: A phantom-based study

PURPOSE Cortical porosity is a key characteristic governing the structural properties and mechanical behaviour of bone, and its quantification is therefore critical for understanding and monitoring the development of various bone pathologies such as osteoporosis. Axial transmission quantitative acoustics has shown to be a promising technique for assessing bone health in a fast, non-invasive, an...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 71 6  شماره 

صفحات  -

تاریخ انتشار 2014