The third decade of cardiac pacing. Multiprogrammable pulse generators.
نویسندگان
چکیده
Cardiac pacing as a clinical discipline is now over 20 years old. The end of the first decade saw the development of the demand pacemaker, the first "intelligent" implantable prosthetic device. Further progress took place mostly in the latter half of the second decade, with the introduction of lithium power sources with greater longevity, miniaturisation of electronic circuits, overall improvement in design with the widespread use of hermetic encapsulation of power sources and components for greater protection, and the development of noninvasive programmability. As we begin the third decade of cardiac pacing, the inexorable and accelerated growth of pacemaker technology has already fostered a large array of sophisticated multiprogrammable pulse generators, with a variety of functions. The complexity of pulse generators will inevitably continue to increase with the promise that devices will be far more specific in their clinical applicability. In 1978, about 36 per cent of all pacemaker implants in the United States used programmable pulse generators' and it appears almost certain that these units will largely or indeed completely replace non-programmable systems in the next few years as confidence and reliability improve and the benefits of non-invasive programming become more widely appreciated. Indeed, the greater longevity of lithium powered pulse generators can in itself be considered an important reason for programmability. It is impossible to predict in advance who will require modification of pacemaker variables and the likelihood of a change in a patient's requirements will undoubtedly increase the longer the same generator remains implanted.
منابع مشابه
Interference from a hand held radiofrequency remote control causing discharge of an implantable defibrillator.
A 46-year-old man with a history of sustained monomorphic ventricular tachycardia underwent an implantation of a third generation multiprogrammable implantable cardioverter defibrillator. One year post implant, while manipulating a remote control to a radiofrequency modulated toy car, the patient experienced a defibrillator discharge not preceded by an arrhythmia prodrome. Subsequent interrogat...
متن کاملProspective Randomized Repeat-Crossover Comparison of Antitachycardia Pacing With Low-Energy Cardioversion
Background. Multiprogrammable antiarrhythmia devices can treat monomorphic ventricular tachycardia (VT) with autodecremental overdrive pacing and/or with low-energy cardioversion. These two methods provide the opportunity to decrease patient discomfort typically experienced with high-energy pulses. Although both therapies are known to be effective, controversy persists over their relative safet...
متن کاملCardiac pacing in children
Twenty patients aged between 12 months and 13 years underwent permanent pacemaker implantation. The main indication for pacing was post-surgical atrioventricular block. The complication rate was high and related mainly to infections and lead system problems. The use of small multiprogrammable pacemakers is expected to reduce the reoperation rate for system malfunction and elective replacement. ...
متن کاملClinical experience with a tiered-therapy, multiprogrammable antiarrhythmia device.
BACKGROUND The purpose of this report is to describe our initial experience with a tiered-therapy, variable detection criteria, multiprogrammable antiarrhythmia device capable of antitachycardia pacing, cardioversion, and defibrillation in 50 cardiac arrest survivors. METHODS AND RESULTS An epicardial lead system was used in 35 patients. A transvenous lead system was used in 15 patients. The ...
متن کاملA prospective randomized repeat-crossover comparison of antitachycardia pacing with low-energy cardioversion.
BACKGROUND Multiprogrammable antiarrhythmia devices can treat monomorphic ventricular tachycardia (VT) with autodecremental overdrive pacing and/or with low-energy cardioversion. These two methods provide the opportunity to decrease patient discomfort typically experienced with high-energy pulses. Although both therapies are known to be effective, controversy persists over their relative safety...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 45 4 شماره
صفحات -
تاریخ انتشار 1981