Single SQUID Multiplexer for Arrays of Voltage-biased Superconducting Bolometers

نویسندگان

  • Jongsoo Yoon
  • John Clarke
  • J. M. Gildemeister
  • Adrian T. Lee
  • M. J. Myers
  • P. L. Richards
  • J. T. Skidmore
  • H. G. Spieler
چکیده

We describe a frequency domain superconducting quantum interference device (SQUID) multiplexer which monitors a row of low-temperature sensors simultaneously with a single SQUID. Each sensor is ac biased with a unique frequency and all the sensor currents are added in a superconducting summing loop. A single SQUID measures the current in the summing loop, and the individual signals are lock-in detected after the room temperature SQUID electronics. The current in the summing loop is nulled by feedback to eliminate direct crosstalk. In order to avoid the accumulation of Johnson noise in the summing loop, a tuned bandpass filter is inserted in series with each sensor. For a 32-channel multiplexer for Voltage-baised Superconducting Bolometer (VSB) with a time constant ~1msec, we estimate that bias frequencies in the range from ~500kHz to ~600kHz are practical. The major limitation of our multiplexing scheme is in the slew rate of a readout SQUID. We discuss a “carrier nulling” technique which could be used to increase the number of sensors in a row or to multiplex faster bolometers by reducing the required slew rate for a readout SQUID.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and characterization of TES bolometers and SQUID readout electronics for a balloon-borne application

We present measurements of the electrical and thermal properties of new arrays of bolometeric detectors that were fabricated as part of a program to develop bolometers optimized for the low photon background of the EBEX balloon-borne experiment. An array consists of 140 spider-web transition edge sensor bolometers microfabricated on a 4” diameter silicon wafer. The designed average thermal cond...

متن کامل

Superconducting Tes Bolometers above 1k

The discovery of High Tc superconductivity led to the exploration of current-biased superconducting bolometers cooled with liquid nitrogen and optimized to view 300K backgrounds at wavelengths beyond 10 μm. If such detectors reach the thermal fluctuation noise limit they would be a great improvement over room temperature pyroelectric detectors and thermopiles for many applications. The supercon...

متن کامل

Antenna-coupled TES Arrays For The BICEP2/Keck and SPIDER polarimeters

The upcoming Cosmic Microwave Background (CMB) experiments BICEP2/Keck and SPIDER will be using planar arrays of polarization sensitive antenna-coupled TES bolometers, operating at frequencies between 96GEIZ and 220 GEIz. At 145 GlTz each array consists of 64 polarimeters (128 TES sensors) and four of these arrays are assembled together to make a focal plane. The detector arrays are integrated ...

متن کامل

Superconducting SET with tunable electromagnetic environment

We have studied the environmental effect on superconducting single-electron transistors (S-SETs) by biasing SSETs with arrays of small-capacitance dc SQUIDs, whose effective impedance can be varied in situ. As the zerobias resistance of the arrays is increased, Coulomb blockade in the S-SET becomes sharper, and the gate-voltage dependence changes from e-periodic to 2e-periodic. The SQUID arrays...

متن کامل

Optimal SQUID based non-destructive test for detecting sub-surface defects with the help of advanced SQUID superconducting sensors and an experimental approach for optimal production method of these sensors from the YBCO superconductor materials

The conventional eddy current method for non-destructive inspection of welding joints has limitations that can examine defects to a certain depth below the surface of the sample and is not suitable for determining deep defects. This limitation can be overcome using the SQUID superconducting sensors. The nonstoichiometric composition of YBCO due to its superconducting temperature and desired cri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001