Comparative studies of RNFL thickness measured by OCT with global index of visual fields in patients with ocular hypertension and early open angle glaucoma

نویسندگان

  • Sergios Taliantzis
  • Dimitris Papaconstantinou
  • Chrysanthi Koutsandrea
  • Michalis Moschos
  • Michalis Apostolopoulos
  • Gerasimos Georgopoulos
چکیده

PURPOSE To compare the functional changes in visual fields with optical coherence tomography (OCT) findings in patients with ocular hypertension, open angle glaucoma, and suspected glaucoma. In addition, our purpose is to evaluate the correlation of global indices with the structural glaucomatous defect, to assess their statistical importance in all the groups of our study, and to estimate their validity to the clinical practice. METHODS One hundred sixty nine eyes (140 patients) were enrolled. The patients were classified in three groups. Group 1 consisted of 54 eyes with ocular hypertension, group 2 of 42 eyes with preperimetric glaucoma, and group 3 of 73 eyes with chronic open angle glaucoma. All of them underwent ophthalmic examination according to a prefixed protocol, OCT exam (Stratus 3000) for retinal nerve fiber layer (RNFL) thickness measurement with fast RNFL thickness protocol and visual fields (VF) examination with Octopus perimeter (G2 program, central 30-2 threshold strategy). Pearson correlation was calculated between RNFL thickness and global index of VF. RESULTS A moderate correlation between RNFL thickness and indices mean sensitivity (MS), mean defect (MD) and loss variance (LV) of VF (0.547, -0.582, -0.527, respectively; P <0.001) was observed for all patients. Correlations of the ocular hypertension and preperimetric groups are weak. Correlation of RNFL thickness with global indices becomes stronger as the structural alterations become deeper in OCT exam. Correlation of RNFL thickness with the global index of VF, in respective segments around optic disk was also calculated and was found significant in the nasal, inferior, superior, and temporal segments. CONCLUSION RNFL average thickness is not a reliable index for early diagnosis of glaucoma and for the follow-up of patients with ocular hypertension. Segmental RNFL thickness seems to be a more reliable index. Deep structural alterations with OCT examination constitute an important indication of early functional changes, even if they are not still detected with achromatic perimetry. The MD index of VF seems to be more sensitive for the follow-up of patients with ocular hypertension.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular Hypertension

OBJECTIVES To investigate the correlation of visual field (VF), pattern electroretinography (PERG) and Fourier domain optical coherence tomography (FD-OCT) results in patients with ocular hypertension (OHT) and early primary open-angle glaucoma (POAG). MATERIALS AND METHODS The study included 72 eyes of 37 patients with early POAG, 76 eyes of 38 patients with OHT, and 60 eyes of 30 controls. ...

متن کامل

Diagnostic ability of macular ganglion cell–inner plexiform layer thickness in glaucoma suspects

The purpose is to assess the diagnostic ability for early glaucoma of macular ganglion cell-inner plexiform layer (GCIPL) thickness in a Chinese population including glaucoma suspects.A total of 367 eyes with primary open-angle glaucoma (168 early glaucoma, 78 moderate glaucoma, and 121 advanced glaucoma), 52 eyes with ocular hypertension (OHT), 59 eyes with enlarged cup-to-disc ratio (C/D), an...

متن کامل

Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments.

PURPOSE To compare retinal nerve fiber layer (RNFL) measurements between two ocular coherence tomography (OCT) instruments (OCT 2000 and Stratus OCT; Carl Zeiss Meditec, Dublin, CA) and compare their diagnostic precision. METHODS One hundred thirty-nine consecutive subjects were imaged (3 x 3.4-mm diameter circular scans) on the same day with each instrument. Thirty-five patients were exclude...

متن کامل

Relationship Between Visual Field Sensitivity and Retinal Nerve Fiber Layer Thickness Measured by Scanning Laser Polarimetry and Optical Coherence Tomography in Normal, Ocular Hypertensive and Glaucomatous Eyes

PURPOSE: To evaluate the correlation between automated achromatic perimetry (AAP) and the output of two retinal nerve fiber layer (RNFL) analysers: scanning laser polarimetry (GDx-VCC) and optical coherence tomography (OCT). METHODS: Quantitative RNFL measurements with GDx-VCC and Stratus-OCT were obtained in one eye from 52 healthy subjects, 38 ocular hypertensive (OHT) patients and 94 glaucom...

متن کامل

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

PURPOSE To compare the peripapillary retinal nerve fiber layer (RNFL) thickness of normal patients and those with various glaucoma diseases by time domain (Stratus) and spectral domain (Spectralis) optical coherence tomography (OCT). METHODS The RNFL thickness as measured by the Stratus and Spectral OCT was compared (paired t-test). The relationship and agreement of RNFL thickness between the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009