Percutaneous epiphysiodesis using transphyseal screws for limb-length discrepancies: high variability among growth predictor models

نویسندگان

  • Bryan C. Monier
  • David D. Aronsson
  • Michael Sun
چکیده

PURPOSE Percutaneous epiphysiodesis using transphyseal screws (PETS) was developed as a minimally invasive outpatient procedure to address limb-length discrepancy (LLD) that allowed immediate postoperative weight bearing and was potentially reversible by removing the screws. The aims of our study were to report our results using PETS for LLD and evaluate the accuracy of three growth predictor models. METHODS Sixteen patients with an average age of 14 years were treated for LLD using PETS. Thirteen patients had screws inserted in a parallel fashion and 3 had crossed screws. We compared the predicted LLD at skeletal maturity using the three growth predictor methods with the actual LLD at skeletal maturity and preoperative LLD with the final LLD at skeletal maturity. RESULTS The mean LLD at skeletal maturity between the predicted and final measurements was 0.2 cm using the Green-Anderson method, 1.4 cm using the Moseley method, and -0.1 cm using the Paley method. The mean preoperative LLD of 3.1 cm was corrected to 1.7 cm at skeletal maturity (p < 0.001). Six patients complained of pain over the screw heads; however, no patient developed an infection or angular deformity. CONCLUSIONS The three growth predictor methods predicted the final LLD within an average of 1.4 cm, but there was high variability. Although PETS improved the LLD by a mean of 1.4 cm, we believe the results would have been better if PETS was performed at an earlier skeletal age.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of different minimally invasive epiphysiodesis techniques in the management of pediatric leg length discrepancies: a systematic review protocol.

REVIEW QUESTION/OBJECTIVE The objective of this review is to synthesize the best available evidence on the use of percutaneous epiphysiodesis for the management of pediatric leg length discrepancies (LLDs). The effectiveness of four different percutaneous epiphysiodesis techniques will be compared, including transphyseal screws (percutaneous epiphysiodesis using transphyseal screws), physeal dr...

متن کامل

Epiphysiodesis Screw Bending.

Percutaneous epiphysiodesis using transphyseal screws is a common method for treatment of limb length discrepancy and angular deformity. The authors report 3 cases of a previously unreported complication following treatment with percutaneous epiphysiodesis using transphyseal screws: bending of the transphyseal screw. In each case, this rare complication was associated with difficult removal of ...

متن کامل

Comparison of three surgical epiphysiodesis techniques for the treatment of lower limb length discrepancy.

Three operative techniques for epiphysiodesis to correct lower limb length discrepancy (LLD) are compared: the Phemister technique, the percutaneous drilling-curettage technique and percutaneous epiphysiodesis using a transphyseal screw. Between 1987 and 2008, 92 patients with LLD were treated by surgical epiphysiodesis. Eighty patients were available for this retrospective study. No statistica...

متن کامل

Transphyseal bioabsorbable screws cause temporary growth retardation in rabbit femur.

A self-reinforced bioabsorbable poly-L-lactide/polyglycolide (SR-PLGA) 80/20 screw 2.0 mm in diameter was implanted transphyseally across the distal growth plate of the right femur in 24 immature rabbits. Radiologic evaluation revealed a mean shortening of 3.1 mm at 3 weeks, 11.1 mm at 6 weeks, 9.3 mm at 24 weeks, 9.0 mm at 48 weeks, and 12.6 mm at 72 weeks compared with the intact contralatera...

متن کامل

Percutaneous medial hemi-epiphysiodesis using a transphyseal screw for caput valgum associated with developmental dysplasia of the hip

BACKGROUND The purpose of this study was to evaluate the radiologic outcome of percutaneous medial hemi-epiphysiodesis using a transphyseal screw for the management of caput valgum associated with developmental dysplasia of the hip (DDH). METHODS Eighteen hips (18 patients) having caput valgum treated with screw hemi-epiphysiodesis were followed for more than 2 years, and were included in thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015