Left Ventricular Decompression During Speed Optimization Ramps in Patients Supported by Continuous-Flow Left Ventricular Assist Devices: Device-Specific Performance Characteristics and Impact on Diagnostic Algorithms.
نویسندگان
چکیده
BACKGROUND Echocardiographic ramp tests have been widely used to help guide speed adjustments and for identification of potential device malfunctions in patients with axial continuous-flow left ventricular assist devices (LVADs) (Heartmate II LVAD [HMII]). Recently, the use of centrifugal-flow LVADs (Heartware LVAD [HVAD]) has been on the rise. The purpose of this study was to evaluate the utility of ramp tests for assessing ventricular decompression in HVAD patients. METHODS AND RESULTS In this prospective study, ramp tests were performed before index hospitalization discharge or at the time of device malfunction. Vital signs, device parameters (including flow), and echocardiographic parameters (including left ventricular end-diastolic dimension [LVEDD], frequency of aortic valve [AV] opening, and valvular insufficiency) were recorded in increments of 100 rpm, from 2,300 rpm to 3,200 rpm. Twenty-six ramp tests were performed, 19 for speed optimization and 7 for device malfunction assessment. The average speed after the speed optimization ramp tests was 2,534.74 ± 156.32 RPM, and the AV closed at a mean speed of 2,751.77 ± 227.16 rpm, with 1 patient's valve remaining open at the maximum speed. The reduction in LVEDD for each speed increase was significantly different when the AV was open or closed, at -0.09 cm/increment and -0.15 cm/increment, respectively (P = .013), which is significantly different than previously established HMII LVEDD slopes. There were also significant changes in overall device flow (P = .001), upper flow (P = .031), and lower flow (P = .003) after AV closure. The power slope did not change significantly after the AV closed (P = .656). Five of the 19 tests were stopped before completion owing to suction events, but all tests reached ≥3,000 rpm. CONCLUSIONS The parameter slopes for the HMII cannot be directly applied to ramp studies in HVAD patients. Overall, the LVEDD slope is drastically smaller in magnitude than the previously reported HMII findings, and speed adjustments were not based on the degree of left ventricular unloading. Therefore, the slope of the LVEDD-rpm relationship is not likely to be helpful in evaluating HVAD function.
منابع مشابه
Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملImaging for ventricular function and myocardial recovery on nonpulsatile ventricular assist devices.
Advances in the field of device support have led to increased use of continuous-flow left ventricular assist devices (LVADs) to improve outcomes in patients with end-stage heart disease. Newer-generation LVADs have become the pump of choice for bridging to heart transplantation and as destination therapy for patients with contraindications to transplantation.1 Different imaging modalities have ...
متن کاملHemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.
BACKGROUND Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied. METHODS AND RESULTS Thirty-four patients undergoing implantation with a pulsatile, ...
متن کاملAdvances in Mechanical Circulatory Support Imaging for Ventricular Function and Myocardial Recovery on Nonpulsatile Ventricular Assist Devices
Advances in the field of device support have led to increased use of continuous-flow left ventricular assist devices (LVADs) to improve outcomes in patients with end-stage heart disease. Newer-generation LVADs have become the pump of choice for bridging to heart transplantation and as destination therapy for patients with contraindications to transplantation.1 Different imaging modalities have ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cardiac failure
دوره 21 10 شماره
صفحات -
تاریخ انتشار 2015