Exposure to sevoflurane and nitrous oxide during four different methods of anesthetic induction.
نویسندگان
چکیده
UNLABELLED The National Institute for Occupational Safety and Health-recommended exposure levels for nitrous oxide exposure are 25 ppm as a time-weighted average over the time of exposure. The exposure limit for halogenated anesthetics (without concomitant nitrous oxide exposure) is 2 ppm. Inhaled sevoflurane provides an alternative to i.v. induction of anesthesia. However, the inadvertent release of anesthetic gases into the room is likely to be greater than that with induction involving i.v. anesthetics. We therefore evaluated anesthesiologist exposure during four different induction techniques. Eighty patients were assigned to one of the induction groups to receive: 1) sevoflurane and nitrous oxide from a rebreathing bag, 2) sevoflurane and nitrous oxide from a circle circuit, 3) propofol 3 mg/kg, and 4) thiopental sodium 5 mg/kg. Anesthesia was maintained with sevoflurane and nitrous oxide via a laryngeal mask. Trace concentrations were measured directly from the breathing zone of the anesthesiologist. During induction, peak concentrations of sevoflurane and nitrous oxide with the two i.v. methods rarely exceeded 2 ppm sevoflurane and 50 ppm nitrous oxide. Concentrations during the two inhalation methods were generally <20 ppm sevoflurane and 100 ppm nitrous oxide. During maintenance, median values were near 2 ppm sevoflurane and 50 ppm nitrous oxide in all groups. Sevoflurane concentrations during inhaled induction frequently exceeded the National Institute for Occupational Safety and Health-recommended exposure ceiling of 2 ppm but mostly remained <20 ppm. Exposure during the maintenance phase of anesthesia also frequently exceeded the 2-ppm ceiling. We conclude that operating room anesthetic vapor concentrations are increased during inhaled inductions and remain increased with laryngeal mask ventilation. IMPLICATIONS We compared waste gas concentrations to sevoflurane and nitrous oxide during four different induction methods. During inhaled induction with a rebreathing bag or a circle circuit system, waste gas concentrations frequently exceed National Institute for Occupational Safety and Health limits of 2 ppm sevoflurane and 50 ppm nitrous oxide. Therefore, we recommend that people at risk (e.g., women of child-bearing age) should pay great attention when using this technique.
منابع مشابه
[Assessment of the cognitive effects of inhalational induction with sevoflurane associated or not with nitrous oxide: a comparative study in adult volunteers.].
BACKGROUND AND OBJECTIVES Anesthetic induction with inhalational agents using a facemask has gained attention since the introduction of sevoflurane. At the same time, the influence of adding nitrous oxide on the pattern of induction and recuperation deserves attention, especially regarding recovery of the cognitive function. The objective of this study was to evaluate the cognitive effects of i...
متن کاملSevoflurane versus propofol for anesthetic induction: a meta-analysis.
UNLABELLED We performed this meta-analysis to compare the characteristics of sevoflurane and propofol for the induction of routine anesthesia and for laryngeal mask airway (LMA) insertion. The variables assessed were 1) time to loss of consciousness, 2) incidence of apnea during induction, 3) induction complications, 4) time for successful LMA insertion, 5) success with LMA insertion on first a...
متن کاملInfluence of nitrous oxide on minimum alveolar concentration of sevoflurane for laryngeal mask insertion in children.
BACKGROUND Inhalational induction with sevoflurane and nitrous oxide is frequently used for Laryngeal Mask Airway (LMA; Laryngeal Mask Company, Henley-on-Thames, United Kingdom) insertion in children. The authors determined the influence of nitrous oxide on the minimum alveolar concentration (MAC) of sevoflurane for LMA insertion. METHODS One hundred twenty unpremedicated children (age, 1-9 y...
متن کاملEnvironmental monitoring during gaseous induction with sevoflurane.
Recent research has shown that gaseous induction in adults with sevoflurane is an acceptable technique. This study was undertaken to assess if gaseous induction using sevoflurane carried in both oxygen alone, and in nitrous oxide and oxygen combined, would provide acceptable pollution levels. As an occupational exposure standard has not been set for sevoflurane, we used the target level of 20 p...
متن کاملAdditive contribution of nitrous oxide to sevoflurane minimum alveolar concentration for tracheal intubation in children.
BACKGROUND To study the interaction between nitrous oxide and sevoflurane during trachea intubation, the authors determined the minimum alveolar concentration of sevoflurane for tracheal intubation (MAC(TI)) with and without nitrous oxide in children. METHODS Seventy-two children aged 1-7 yr were assigned randomly to receive one of three end-tidal concentrations of nitrous oxide and one of fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesia and analgesia
دوره 88 4 شماره
صفحات -
تاریخ انتشار 1999