Assessing the quality of glucose monitor studies: a critical evaluation of published reports.
نویسندگان
چکیده
BACKGROUND In recent years, a large number of studies have been published on the performance of glucose monitors. The quality of these reports is not known. METHODS We searched the PubMed database for performance evaluations of handheld glucose monitors published from August 2002 to November 2006. Relevant articles were compared to 20 recommendations from the Standards for Reporting Diagnostic Accuracy (STARD) and 18 recommendations from the Clinical and Laboratory Standards Institute (CLSI). RESULTS A total of 52 reports met our inclusion criteria and were reviewed. None (0%) of the reports conformed to all 38 STARD and CLSI recommendations. The range of compliance to these recommendations varied widely (median 53%; range 21%-84%). Only 1 study of the 52 reported following a CLSI recommendation for checking reference test results. Fewer than half (42%) of the reports contained STARD-recommended statements regarding how and when comparative measurements were performed. CONCLUSIONS None of the glucose monitor reports from our review conformed to all STARD and CLSI recommendations. Our finding that the average rate of compliance to recommendations was low suggests that many of the researchers did not follow published recommendations for study design, methodology, and reporting and that study quality and conclusions may have been affected. Future studies evaluating the performance of glucose monitoring systems should be carefully designed and follow published recommendations for methodological and reporting quality.
منابع مشابه
Critique and evaluation of published articles quality of Health Sciences qualitative Researches Journal based on CASP scale
Introduction: Recently, rate of journals and published article in the medical sciences has grown, but the quality of these journals and published articles should be criticized. Therefore, this study was conducted with the aim of criticizing quality of published studies in the qualitative research in health sciences journal based on the CASP scale. Methods: This study has been done with a cro...
متن کاملCritical Appraisal of the Validity and Reliability of the Quantitative Studies Published in Iranian Nursing Journals
Background: Despite progression of knowledge of nursing researcher about importance of psychometric principles of instruments of studies but it seems that this subject is not used correctly in nursing studies. This study is designed to critically assess the validity and reliability of instruments applied in studies published in Iranian nursing journals Methods: This study is a critical review o...
متن کاملA review of 17 years of application of partnership care model on the consequences of chronic diseases: Describing and assessing the quality of the methodology of papers
Background: Regarding the widespread prevalence of chronic diseases, nurses need to understand the choices, priorities, and abilities of patients in reality, their communication, and the social context in order to play their professional role and responsibility. This review study was conducted with two purposes: determining the effect of partnership-care-model (PCM) on the outcomes of chronic d...
متن کاملQuality of published Iranian medical education research studies: a systematic review
Background :Research in medical education has been paid more attention than before however the quality of research reporting has not been comprehensively appraised.To evaluate the methodological and reporting quality of Iranian published medical education articles. Methods: Articles describing medical students, residents, fellows or program evaluation were included. Articles related to cont...
متن کاملAnalytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 53 6 شماره
صفحات -
تاریخ انتشار 2007