The importance of cleaning for the overall results of processing endoscopes.

نویسندگان

  • H Martiny
  • H Floss
  • B Zühlsdorf
چکیده

Reprocessing comprises three steps: cleaning, disinfection and-if required-sterilisation. While the extents of disinfection and of sterilisation are quantitatively defined, there are only imprecise (qualitative) definitions of cleaning. There are two main reasons for accurate cleaning. First organic and inorganic materials that remain on inner and outer surfaces will interfere with the efficacy of the disinfectants. In case of endoscopes this will lead to channel blockages; they remain undisinfected. Second the bioburden found on endoscopes after use can be very high. Data available demonstrate that a bacterial burden of up to 10(9)cfu/endoscope channel can be expected. Therefore it is necessary to perform a thorough cleaning. Studies using endoscopes showed a reduction in microbial counts by a factor of approximately 10(4) by cleaning (manual and mechanical). Therefore in 2001 the German Society of Hospital Hygiene (DGKH) specified its requirements and recommendations for determining cleaning efficacy separately from those for disinfection. Cleaning and disinfecting can be done manually or mechanically, but it seems impossible to validate manual processes. However our studies in two different washer-disinfectors (WD) showed differences in cleaning efficacy. The tested cleaning processes showed different efficacies. Not all cleaning processes showed better results than water alone with regard to visible cleanliness and to a microbiological reduction E. faecium. Our results show that the evaluation of cleanliness exclusively by visible inspection is not sufficient, particular for the lumens of endoscopes. The results also show that a cleaning process may be very effective also in reducing micro-organisms present.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Guideline Implementation: Processing Flexible Endoscopes.

The updated AORN "Guideline for processing flexible endoscopes" provides guidance to perioperative, endoscopy, and sterile processing personnel for processing all types of reusable flexible endoscopes and accessories in all procedural settings. This article focuses on key points of the guideline to help perioperative personnel safely and effectively process flexible endoscopes to prevent infect...

متن کامل

Elimination of high titre HIV from fibreoptic endoscopes

Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the k...

متن کامل

Elimination of high titre HIV from fibreoptic endoscopes.

Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the k...

متن کامل

WHO EMRO | Reprocessing practices for gastrointestinal endoscopes: a multicentre study in Egyptian university hospitals PDF version Short communication

The aim of this study was to assess the practices of health care workers during gasterointestinal endoscope reprocessing, evaluate their knowledge about reprocessing, and verify their compliance with laboratory and microbiological tests in endoscopy units at Zagazig University and Fayoum University hospitals. All nursing staff on duty from 10 endoscopy units, with 16 flexible endoscopes, were i...

متن کامل

Modofication of the Sarcheshmeh copper complex flotation circuit in response to a reduction in feed grade

The new copper processing plant of the Sarcheshmeh copper complex consists of two parallel circuits. After a primary crushing, the ore is sent to a SAG mill, and the product is further ground in a ball mill. The overflow of the hydrocyclones is fed to a flotation circuit that contains 8 rougher tank cells (RCS130), 3 cleaner cells (RCS50), 5 scavenger cells (RCS50), and a flotation column (as r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of hospital infection

دوره 56 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2004