Minimally invasive plate osteosynthesis for osteofibrous dysplasia of the tibia: a case report.
نویسندگان
چکیده
Osteofibrous dysplasia occurs most frequently in the tibia and may result in deformity and pathological fracture. We report one such case in a 6-year-old girl who underwent minimally invasive plate osteosynthesis using a locking compression plate. The varus deformity of the tibia was manually corrected, and the plate was inserted without extensive surgical exposure. At 20-week follow-up, the fracture had healed completely, and she had returned to normal daily living. At 3-year follow-up, radiographs showed no progression of the varus deformity. Minimally invasive plate osteosynthesis is useful for treatment of pathological fractures caused by osteofibrous dysplasia. It preserves blood flow at the fracture site, leading to good bone healing and stability to prevent further deformity and an early return to daily activity.
منابع مشابه
Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures
Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...
متن کاملMinimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Diametaphyseal Tibia Fracture
Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology of distal t...
متن کاملComparative study of intramedullary interlocking nailing and minimally invasive percutaneous plate osteosynthesis (MIPO) in extra articular distal tibial fracture
Introduction: Tibia is one of the most commonly fractured long bone of the body. Distal tibia fractures are primarily located within a square based on the width of the distal tibia. Treatment of distal tibia fracture is challenging because of its unique anatomical characteristics of subcutaneous location with precarious blood supply and proximity to the ankle joint. Minimally invasive plate ost...
متن کاملEarly Results of Minimally Invasive Percutaneous Plate Osteosynthesis for Fractures of the Distal Tibia: A Retrospective Case Series and Review of the Literature
Minimally invasive percutaneous plate osteosynthesis was developed on the concept that preservation of the soft tissue envelope during surgical management of distal tibial fractures is of paramount importance. We report on our early experience using this technique over a 1-year period with 14 such injuries that were treated by a locking compression plate via minimally invasive surgery. The surg...
متن کاملMinimally invasive percutaneous plate fixation of distal tibia fractures.
We report a series of 42 patients reviewed at a mean of 19.6 months after treatment of distal tibial and pilon fractures using the AO distal tibia locking plate with a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. Mean time to union was 22.4 weeks. All fractures united with acceptable alignment and angulation. Two cases of superficial infection were noted, with one cas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic surgery
دوره 18 3 شماره
صفحات -
تاریخ انتشار 2010