Biomechanical evaluation of bone screw fixation with a novel bone cement
نویسندگان
چکیده
BACKGROUND Bone cement augmentation is commonly used to improve the fixation stability of orthopaedic implants in osteoporotic bone. The aim of this study was to evaluate the effect of novel bone cements on the stability of bone screw fixation by biomechanical testing and to compare them with a conventional Simplex(®)P bone cement and requirements of the standards. METHODS Basic biomechanical properties were compared with standard tests. Adhesion of bone cements were tested with polished, glass blasted and corundum blasted stainless steel surfaces. Screw pullout testing with/without cement was carried out using a synthetic bone model and cancellous and cortical bone screws. RESULTS All the tested bone cements fulfilled the requirements of the standard for biomechanical properties and improved the screw fixation stability. Even a threefold increase in shear and tensile strength was achieved with increasing surface roughness. The augmentation improved the screw pullout force compared to fixation without augmentation, 1.2-5.7 times depending on the cement and the screw type. The good biomechanical properties of novel bone cement for osteoporotic bone were confirmed by experimental testing. CONCLUSION Medium viscosity of the bone cements allowed easy handling and well-controlled penetration of bone cement into osteoporotic bone. By proper parameters and procedures it is possible to achieve biomechanically stable fixation in osteoporotic bone. Based on this study, novel biostable bone cements are very potential biomaterials to enhance bone screw fixation in osteoporotic bone. Novel bone cement is easy to use without hand mixing using a dual syringe and thus makes it possibility to use it as required during the operation.
منابع مشابه
Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملThe Most Appropriate Reconstruction Method Following Giant Cell Tumor Curettage: A Biomechanical Approach
Giant cell tumor (GCT) is a primary and benign tumor of bone, albeit locally aggressive in some cases, such as in the epi-metaphyseal region of long bones, predominantly the distal end of femur and proximal end of tibia (1). There are a variety of treatments for a bone affected by GCT, ranging from chemotherapy, radiotherapy, embolization, and cryosurgery, to surgery with the use of chemical or...
متن کاملInjectable calcium phosphate cement for augmentation around cancellous bone screws. In vivo biomechanical studies.
In lower cancellous apparent bone density, it can be difficult to achieve adequate screw fixation and hence stable fracture fixation. Different strategies have been proposed, one of them is through augmentation using calcium phosphate cement in the region at or close to the screw thread itself. To support the hypothesis of an improved screw fixation technique by augmentation of the bone surroun...
متن کاملSurgical Strategies to Improve Fixation in the Osteoporotic Spine: The Effects of Tapping, Cement Augmentation, and Screw Trajectory
Study Design Biomechanical study of pedicle screw fixation in osteoporotic bone. Objective To investigate whether it is better to tap or not tap osteoporotic bone prior to placing a cement-augmented pedicle screw. Methods Initially, we evaluated load to failure of screws placed in cancellous bone blocks with or without prior tapping as well as after varying the depths of tapping prior to screw ...
متن کاملBiomechanical Performance of an Injectable Screw for Fixation in Severely Osteoporotic Bone: an Experimental Study
INTRODUCTION Pedicle screw fixation in a severely osteoporotic spine remains a challenge for orthopaedic surgeons. Previous studies have demonstrated that pedicle screw fixation is highly correlated to the bone mineral density [1], and increasing the screw’s pullout strength can be achieved using a variety of methods, these include the use of pedicle screws with various designs [2,3]. However, ...
متن کامل