A technique for unknotting an intracardiac flow-directed balloon catheter.
نویسندگان
چکیده
Described is an unusual complication occurring during right-sided cardiac catheterization using a 7F flow-directed balloon catheter. During an attempt to direct the catheter from the main pulmonary artery into the pulmonary wedge position, the tip became entangled in a loop of catheter and knotted. Initially, all attempts to unknot or remove the catheter failed. A movable core guide wire was passed through the major lumen of the catheter, resulting in the immediate unknotting of the catheter, thus allowing its withdrawal.
منابع مشابه
Knotting of intracardiac flow-directed balloon catheter. Simple surgical method of removal.
A complete knot occurred in a 7F flow-directed balloon catheter inserted through the right internal jugular vein. The patient was intubated and placed under positive pressure ventilation. After gaining surgical exposure of the venipuncture site, a purse-string of Prolene 4--0 suture was placed around it. The patient was placed in the Trendelenburg position and the knotted catheter withdrawn, wh...
متن کاملSegmental pulmonary angiography in the critically-ill patient using a flow-directed catheter.
Selective pulmonary angiography was performed using a flow-directed, balloon-tipped catheter in 20 consecutive intensive care unit patients requiring heart catheterizations on the right side for hemodynamic monitoring. No morbidity was encountered from this procedure. Adequate quality balloon-occlusion angiographs were obtained with a portable chest roentgenogram in 17 (85 percent) but appeared...
متن کاملPreservation of distal coronary perfusion during prolonged balloon inflation with an autoperfusion angioplasty catheter.
A newly designed balloon coronary angioplasty catheter that allows passive antegrade blood flow during balloon inflation (autoperfusion catheter) was compared with a standard balloon coronary angioplasty catheter. In a randomized sequence, inflations were performed for 3 min in the left circumflex coronary artery of 12 dogs with the standard catheter followed by the autoperfusion catheter or vi...
متن کاملIntracardiac Infection at the Tip of Hemodialysis Catheter: Life threatening Morbidity
Endocarditis and intracardiac infection have been increased recently especially in dialysis dependent renal failure patients. This is usually intractable infection to broad spectrum Antibiotic therapy and in most cases surgical intervention was necessary. We have presented 45 years old man with intracardiac infection at the tip of dialysis catheter that after catheter removal intracardiac infec...
متن کاملThe naughty knot in catheterisation laboratory.
To cite: Mahla H, Kondethimmanahally Rangaiah SK, Ramesh D, et al. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2014204127 DESCRIPTION A 60-year-old man presented to the emergency department with multiple syncopal episodes. A 12-lead ECG revealed complete heart block with a ventricular rate of 50 bpm (figure 1). Emergency temporary pacing was performed through ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 67 6 شماره
صفحات -
تاریخ انتشار 1975